Labcorp test 096339, CPT 86225. Specimen: Serum. Turnaround: 2 - 3 days.

Anti-dsDNA (Double-stranded) Antibodies is Labcorp test code 096339, billed with CPT 86225. Specimen: Serum. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code096339
CPT86225
LOINC5130-0
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 3 days
Storage / transportRoom temperature

Also known as: Anti-N-DNA; Antinative DNA

Test includes

Semiquantitative result of IgG class antibodies

Use

Specific assay for confirming the diagnosis of systemic lupus erythematosus (SLE)

Methodology

Multiplex flow immunoassay

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Hemolysis; icterus; lipemia; bacterial contamination

Reference range

• Negative: <5 IU/mL • Equivocal: 5−9 IU/mL • Positive: >9 IU/mL

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

Low antibody levels may be found in other connective tissue diseases.

LOINC map

Result codeResult nameUnitsResult LOINC
096343Anti-DNA (DS) Ab QnIU/mL5130-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86225

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation