Labcorp test 505770, CPT 83516, 86160, 86225. Specimen: Serum, EDTA plasma with Futhan (frozen). Turnaround: 3 - 5 days.
Lupus Monitor Profile is Labcorp test code 505770, billed with CPT 83516, 86160, 86225. Specimen: Serum, EDTA plasma with Futhan (frozen). Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
Test code505770
CPT83516; 86160(x4); 86225
LOINC4485-9, 4488-3, 4498-2, 4501-3
SpecimenSerum, EDTA plasma with Futhan (frozen)
Volume2 mL serum, 2 mL EDTA plasma with Futhan
ContainerGel-barrier tube, lavender-top (EDTA) tube, screw cap tube with Futhan
Turnaround time3 - 5 days
Test includes
Complement C3 [006452]; Complement C3a [004220]; Complement C4 [001834]; Complement C4a [004330]; dsDNA Antibody by IFA, Crithidia luciliae, with Reflex to Titer [096346]; Anti-C1Q Ab, IgG [505710]
Use
This profile is used to aid in monitoring treatment for Lupus patients.
Methodology
See individual components.
Special instructions
State the patient's sex and age on the test request form.
For Complement C3a [004220] and Complement C4a [004330]: Futhan preservative must be added to samples immediately after collection. Collection kits containing this preservative are available as Labcorp Part No. 78946.
Testing for Anti-C1q Ab, IgG currently is not available in New York state.
Limitations
For Complement C3a [004220] and Component C4a [004330]: Results of this test are labeled for research purposes only by the assay's manufacturer. The performance characteristics of this assay have not been established by the manufacturer. The result should not be used for treatment or for diagnostic purposes without confirmation of the diagnosis by another medically established diagnostic product or procedure. The performance characteristics were determined by Labcorp.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| Complement C3, Serum | mg/dL | | 4485-9 |
| Complement C3a | ng/mL | | 4488-3 |
| Complement C4, Serum | mg/dL | | 4498-2 |
| Complement C4a | ng/mL | | 4501-3 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83516, 86160, 86225
- 21-Hydroxylase Autoantibodies, Serum
ARUP LaboratoriesTest code 3001962CPT 83516Serum Separator Tube (SST) or Plain Red.TAT 2-7 days
- Acetylcholine Receptor and Striated Muscle Antibodies Reflexive Panels, and Titin Antibody
Cleveland Clinic LaboratoriesTest code ACESTRCPT 83516, 86041, 86042, 86255SerumTAT 2 - 9 days
- Acetylcholine Receptor Antibodies and Striated Muscle Antibodies Reflexive Panels, and Titin Antibody
ARUP LaboratoriesTest code 2005639CPT 83516, 86041, 86042, 86043, 86255, 86256Plain red top or Serum Separator Tube (SST).TAT 1-8 days
- Adrenal 21-Hydroxylase Autoantibodies (Endocrine Sciences)
LabcorpTest code 504805CPT 83516SerumTAT 7 - 10 days
- ALLOGEN AutoAntibody
Cleveland Clinic LaboratoriesTest code TTAUTOCPT 83516Whole bloodTAT 15 days
- ANCA Profile (RDL)
LabcorpTest code 520149CPT 83516, 86036SerumTAT 7 - 10 days
- ANCA-Associated Vasculitis Profile (ANCA/MPO/PR3)
ARUP LaboratoriesTest code 3003745CPT 83516, 86036Serum separator tube.TAT 2-5 days
- Anti IgE
Cleveland Clinic LaboratoriesTest code ANTIGECPT 83516SerumTAT 6 - 8 days
- Anti-C1q Antibody, IgG
ARUP LaboratoriesTest code 2007601CPT 83516Serum separator tube.TAT 1-15 days
- Anti-C1q Antibody, IgG
Cleveland Clinic LaboratoriesTest code AC1QGGCPT 83516SerumTAT 2 - 16 days
- Anti-Carbamylated Protein (CarP) Antibody
LabcorpTest code 520311CPT 83516SerumTAT 7 - 10 days
- Anti-CEP-1 Ab, IgG (RDL)
LabcorpTest code 520133CPT 83516SerumTAT 7 - 10 days
- Anti-cN-1A (NT5c1A) IBM
Cleveland Clinic LaboratoriesTest code CN1AABCPT 83516SerumTAT 8 - 11 days
- Anti-cN-1A Ab (NT5c1A) IBM (RDL)
LabcorpTest code 520061CPT 83516SerumTAT 7 - 10 days
- Anti-Dense Fine Speckled Protein 70 kDa (DFS70) Ab
LabcorpTest code 520313CPT 83516SerumTAT 7 - 10 days
- Anti-EJ Ab (RDL)
LabcorpTest code 520026CPT 83516SerumTAT 14 - 21 days
- Anti-ENA6 Plus DFS70Ab Profile
LabcorpTest code 520301CPT 83516, 86235SerumTAT 14 - 21 days
- Anti-Fodrin Antibodies, IgG & IgA (RDL)
LabcorpTest code 520134CPT 83516SerumTAT 7 - 14 days
- Anti-Glomerular Basement Membrane Antibodies (RDL)
LabcorpTest code 520137CPT 83516SerumTAT 7 - 14 days
- Anti-GP-210 Ab (RDL)
LabcorpTest code 520139CPT 83516SerumTAT 7 - 14 days
- Anti-gp210 Antibody, IgG
ARUP LaboratoriesTest code 3002477CPT 83516Serum separator tube (SST).TAT 1-8 days
- Anti-HMGCR Ab
LabcorpTest code 520385CPT 83516SerumTAT Three times per week
- Anti-Ku Ab (RDL)
LabcorpTest code 520030CPT 83516SerumTAT 14 - 21 days
- Anti-MCV Antibody
LabcorpTest code 520375CPT 83516SerumTAT 10 days
- Anti-MDA-5 Ab (CADM-140) (RDL)
LabcorpTest code 520002CPT 83516SerumTAT 7 - 10 days
- Anti-Mi-2 Ab (RDL)
LabcorpTest code 520000CPT 83516SerumTAT 14 - 21 days
- Anti-MPO Ab (RDL)
LabcorpTest code 520297CPT 83516SerumTAT 3 - 5 days
- Anti-NXP-2 (P140) Ab (RDL)
LabcorpTest code 520004CPT 83516SerumTAT 7 - 10 days
- Anti-OJ Ab (RDL)
LabcorpTest code 520028CPT 83516SerumTAT 14 - 21 days
- Anti-Phospholipase A2 Receptor (PLA2R) Antibody, IgG by ELISA
ARUP LaboratoriesTest code 3016767CPT 83516Serum separator tube.TAT 1-7 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.