Sound Lab Consultants › National Lab Test Directory › Labcorp › Sjögren's Antibodies (Anti-SS-A/Anti-SS-B)
Sjögren's Antibodies (Anti-SS-A/Anti-SS-B): Labcorp test 012708
Labcorp test 012708, CPT 86235. Specimen: Serum. Turnaround: 1 - 3 days.
Sjögren's Antibodies (Anti-SS-A/Anti-SS-B) is Labcorp test code 012708, billed with CPT 86235. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code012708
CPT86235(x2)
LOINC103139-2, 17791-5, 17792-3
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 3 days
Storage / transportRoom temperature
Also known as: Anti-La; Anti-Ro
Test includes
Semiquantitative result of IgG class antibodies
Use
Aids in the diagnosis of Sjögren's syndrome (especially with vasculitis) and lupus patients with Sjögren's overlap syndrome.
Methodology
Multiplex flow immunoassay
Stability
| Temperature | Period |
|---|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Hemolysis; icterus; lipemia; bacterial contamination
Reference range
0.0−0.9 AI
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 012684 | Sjogren's Anti-SS-A | AI | 17792-3 |
| 012692 | Sjogren's Anti-SS-B | AI | 17791-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86235
- ANA 12 Plus Profile, Do All (RDL)
- ANA 12 Profile, Do All (RDL)
- ANA Multiplex, Panel 1 with Reflexes
- ANA Screen,IFA, with Reflex to Titer and Pattern/Sjogren's Panel 2
- ANAlyzeR™ ANA, IFA with Reflex Titer/Pattern, Systemic Autoimmune Panel 1
- Anti-Centromere Ab by EIA (Enzyme Immunoassay)
- Anti-Centromere Ab by IFA (RDL)
- Anti-Chromatin Ab, IgG (RDL)
- Anti-ENA Abs (RDL)
- Anti-ENA6 Plus DFS70Ab Profile
- Anti-Histone Ab (RDL)
- Anti-Jo-1
- Anti-Jo-1 Ab (RDL)
- Anti-La (SS-B) Ab (RDL)
- Anti-PM/Scl-100 Ab (RDL)
- Anti-PM/Scl-75 Ab (RDL)
- Anti-RNA Polymerase III (RDL)
- Anti-Ro Profile, Ro52 and Ro60 (Anti-SS-A 52 kD and Anti-SS-A 60 kD Separately)
- Anti-Ro, Total (Combined Anti-SS-A 52 kD and Anti-SS-A 60 kD Together)
- Anti-Ro52 (SS-A 52kD) (RDL)
- Anti-Scl-70 Ab (RDL)
- Anti-Sm Ab (RDL)
- Anti-SS-A/60 kD, Ro 60
- Anti-Synthetase Profile (RDL)
- Anti-TIF-1gamma Ab (RDL)
- Anti-U1 RNP Ab (RDL)
- Anti-U2 RNP Ab (RDL)
- Anti-U3 RNP Antibodies (Fibrillarin) (RDL)
- Anticentromere B Antibodies
- Antichromatin Antibodies
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation