Prothrombin Time (PT) (Spe): Labcorp test 005199
Labcorp test 005199, CPT 85610. Specimen: Whole blood or plasma. Turnaround: Within 1 day.
Also known as: Prothrombin Time Assay; Protime; PT
Test includes
International normalized ratio (INR); prothrombin time
Use
This test is used for the evaluation of the extrinsic coagulation system and to aid in screening for congenital and acquired deficiencies of factors II, V, VII, X and fibrinogen. This test is used clinically for the therapeutic monitoring of warfarin (Coumadin®) anticoagulant therapy.
Methodology
Prothrombin time reagent containing thromboplastin and calcium chloride is mixed with the patient plasma and the time to clot formation is measured photo-optically. The calcium chloride overcomes the citrate anticoagulant and allows the tissue factor in the thromboplastin to initiate coagulation. The prolongation of the clotting time correlates with the degree of deficiency or inhibition of the extrinsic pathway factors.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Causes for rejection
Clotted specimen; hemolysis; tube <90% full; improper labeling; specimen collected in tube other than 3.2% citrate; refrigerated specimen
Reference range
See table. Age Range Prothrombin Time (PT) 1 day 14.4−16.4 sec 3 days 13.5−16.4 sec 1 to 11 m 11.5−15.3 sec 1 to 5 y 12.1–14.5 sec 6 to 10 y 11.7−15.1 sec 11 to 16 y 12.7−16.1 sec >16 y 12.2 –14.9 sec International Normalized Ratio (INR) 0 to 1 m 0.9−1.4 >1 m 0.9−1.2
Special instructions
Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please order the serial monitoring test, 485199. If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer Coagulation Collection Procedures for directions.
Limitations
The PT test may not be sensitive to slight deficiencies of single factors. Heparin can extend the PT. Lupus anticoagulants may affect prothrombin time producing results that do not accurately reflect the true level of anticoagulation. The PT (and aPTT) results can be extended in patients receiving antithrombin anticoagulants such as hirudin and argatroban. These patients can be monitored for warfarin effectiveness with a chromogenic factor X assay, which is not affected by lupus anticoagulant or thrombin inhibitors.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 115107 | INR | 6301-6 | |
| 015289 | Prothrombin Time | sec | 5902-2 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85610
- Abnormal Bleeding Profile
- Antiphospholipid Syndrome Reflex Panel
- Coag Core Panel
- DIC Panel
- Disseminated Intravascular Coagulation (DIC) Profile
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Drug-Induced Liver Injury Profile
- Elevated PT and PTT Mixing Panel
- Hypercoagulation Diagnostic Interpretive Panel
- Inhibitor Assay, PT with Reflex to PT 1:1 Mix
- Lupus Anticoagulant Diagnostic Interpretive Panel
- Lupus Anticoagulant Reflex Panel
- Menorrhagia Profile
- Prolonged Clot Time Reflexive Profile
- Prothrombin Time
- Prothrombin Time
- Prothrombin Time (PT)
- Prothrombin Time (PT) (Serial Monitor)
- Prothrombin Time (PT) and Partial Thromboplastin Time (PTT)
- Prothrombin Time (PT) Mixing Study
- Prothrombin Time/International Normalized Ratio
- Thrombotic Risk Reflex Panel
- von Willebrand Diagnostic Interpretive Panel (Limited)
- Menorrhagia Profile
- Prothrombin Time (PT)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation