Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Neutrophil to Lymphocyte Ratio (NLR), Complete Blood Count (CBC) With Differential and Platelet

Neutrophil to Lymphocyte Ratio (NLR), Complete Blood Count (CBC) With Differential and Platelet: Labcorp test 005013

Labcorp test 005013, CPT 85025. Specimen: Whole blood. Turnaround: Within 1 day.

Neutrophil to Lymphocyte Ratio (NLR), Complete Blood Count (CBC) With Differential and Platelet is Labcorp test code 005013, billed with CPT 85025. Specimen: Whole blood. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code005013
CPT85025
LOINC4544-3, 6690-2, 718-7, 785-6, 787-2, 789-8
SpecimenWhole blood
VolumeFill tube to capacity.
Minimum volume0.5 mL (500 μL for pediatric microtainer capillary tubes; fill tube to capacity). Note: This volume does not allow for repeat testing.
ContainerLavender-top (EDTA) tube
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Also known as: CBC/D/Plt+NLR

Use

NLR (Neutrophil to Lymphocyte Ratio) is a biomarker that can be used as an indication of subclinical inflammation. NLR is a calculation based on the Absolute Neutrophil Count divided by the Absolute Lymphocyte Count determined by the peripheral blood CBC differential. This calculation, according to recent literature, is useful in assessing the likelihood of severe progression of disease in SARS-CoV-2 positive patients. CBC:A screening test to evaluate overall health; detect and or identify a wide range of hematologic disorders; assist in managing medications/chemotherapeutic decisions.

Methodology

Automated cell counter with mixed technologies; NLR is a Calculation

Collection instructions

Invert tube 8 to 10 times immediately after tube is filled at the time of collection.

Stability

TemperaturePeriod
Room temperature1 day
Refrigerated3 days
FrozenUnstable
Freeze/thaw cyclesUnstable

Causes for rejection

Hemolysis; clotted specimen; specimen drawn in any anticoagulant other than EDTA; specimen diluted or contaminated with IV fluid; tube not filled with minimum volume; improper labeling; transfer tubes with whole blood; specimen received with plasma removed (plasma is used for other testing)

LOINC map

Result codeResult nameUnitsResult LOINC
WBCx10E3/uL6690-2
RBCx10E6/uL789-8
Hemoglobing/dL718-7
Hematocrit%4544-3
MCVfL787-2
MCHpg785-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85025

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation