Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Iron Deficiency Anemia Cascade With Complete Blood Count (CBC) With Differential

Iron Deficiency Anemia Cascade With Complete Blood Count (CBC) With Differential: Labcorp test 004800

Labcorp test 004800, CPT 85025. Specimen: Serum and whole blood. Turnaround: Within 5 days.

Iron Deficiency Anemia Cascade With Complete Blood Count (CBC) With Differential is Labcorp test code 004800, billed with CPT 85025. Specimen: Serum and whole blood. Turnaround time: Within 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004800
CPT85025
LOINC4544-3, 6690-2, 718-7, 787-2, 789-8
SpecimenSerum and whole blood
Volume4 mL serum and 4 mL whole blood (fill tube to capacity)
Minimum volumeSerum: 2 mL Whole blood: 0.5 mL or 500 µL for pediatric microtainer capillary tubes; venous tube collection: fill tube to capacity
ContainerGel-barrier tube and lavender-top (EDTA) tube
Turnaround timeWithin 5 days
Storage / transportMaintain one serum and lavender-top tube at room temperature. Refrigerate one serum transport tube.

Use

This test is used to determine iron deficiency anemia.

Methodology

See individual test components.

Collection instructions

Serum: Separate serum from cells within 45 minutes of collection. Lavender-top: Invert tube 8 to 10 times immediately after tube is filled at the time of collection.

Stability

TemperaturePeriod
Room temperatureSerum: 14 days
Whole blood: 1 dayRefrigerated
Serum: 14 daysWhole blood: 3 days
FrozenSerum: 14 days

Causes for rejection

Serum: Hemolysis; specimen clotted; improper labeling; EDTA, yellow-top tube, citrate or oxalate plasma specimen Whole blood: Hemolysis; clotted specimen; specimen drawn in any anticoagulant other than EDTA; specimen diluted or contaminated with IV fluid; tube not filled with minimum volume; improper labeling; transfer tubes with whole blood; specimen received with plasma removed (plasma is used for other testing)

Special instructions

Note special reflexing: If Hemoglobin (Hb) [005041] is low, test will reflex to Ferritin [004598]. If Ferritin is normal, test will reflex to Iron and Total Iron-binding Capacity (TIBC) [001321]. Depending on results of Iron and TIBC, test may reflex to Soluble Transferrin Receptor [143305], all at an additional charge or CPT code.

LOINC map

Result codeResult nameUnitsResult LOINC
WBCx10E3/uL6690-2
RBCx10E6/uL789-8
Hemoglobing/dL718-7
Hematocrit%4544-3
MCVfL787-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85025

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation