Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Inflammatory Bowel Disease Differentiation Panel

Inflammatory Bowel Disease Differentiation Panel: ARUP Laboratories test 3003748

ARUP Laboratories test 3003748, CPT 86036, 86671. Specimen: Serum separator tube (SST).. Turnaround: 1-4 days.

Inflammatory Bowel Disease Differentiation Panel is ARUP Laboratories test code 3003748, billed with CPT 86036, 86671. Specimen: Serum separator tube (SST).. Turnaround time: 1-4 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3003748
CPT86036; 86671 x2
LOINC11526-1, 21419-7, 29967-7, 47320-7, 47321-5, 62364-5
SpecimenSerum separator tube (SST).
Turnaround time1-4 days
Storage / transportRefrigerated.

Also known as: S. cerevisiae Ab; Atypical perinuclear anticytoplasmic neutrophil IgG; ASCA; atypical p-ANCA Ab; atypical p-ANCA IgG; Atypical perinuclear anticytoplasmic neutrophil Ab; IBD Differentiation Profile; Saccharomyces cerevisiae Antibody

Use

Recommended panel for the evaluation of patients at risk for inflammatory bowel disease. May also be useful in differentiating patients with ulcerative colitis (UC) from those with Crohn disease (CD).

Methodology

Semi-Quantitative Indirect Fluorescent Antibody (IFA)/Semi-Quantitative Enzyme Immunoassay (EIA)

Collection instructions

Separate from cells ASAP or within 2 hours of collection. Transfer 1.5 mL serum to an ARUP standard transport tube. (Min: 0.6 mL)

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 30 days (avoid repeated freeze/thaw cycles)

Patient preparation

N/A

Causes for rejection

Contaminated, heat-inactivated, hemolyzed, or severely lipemic specimens.

Reference range

Test Number Components Reference Interval S. cerevisiae Antibody, IgG 20.0 Units or less Negative 20.1-24.9 Units Equivocal 25.0 Units or greater Positive S. cerevisiae Antibody, IgA 20.0 Units or less Negative 20.1-24.9 Units Equivocal 25.0 Units or greater Positive ANCA IFA Titer Less than 1:20 ANCA IFA Pattern None Detected

Remarks

N/A

Performed

Mon, Wed, Fri

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0050562S. cerevisiae Antibody, IgG47321-5
0050563S. cerevisiae Antibody, IgA47320-7
2013448Inflammatory Bowel Disease Interp62364-5
3003764ANCA IFA Pattern21419-7
3003765ANCA IFA Titer29967-7
3003768EER Inflammatory Bowel Diseases11526-1

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86036, 86671

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation