Sound Lab Consultants › National Lab Test Directory › Labcorp › Hypersensitivity Pneumonitis Profile

Hypersensitivity Pneumonitis Profile: Labcorp test 660670

Labcorp test 660670, CPT 86331, 86602, 86606, 86609, 86671. Specimen: Serum. Turnaround: 4 - 6 days.

Hypersensitivity Pneumonitis Profile is Labcorp test code 660670, billed with CPT 86331, 86602, 86606, 86609, 86671. Specimen: Serum. Turnaround time: 4 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code660670
CPT86331; 86602(x2); 86606; 86609; 86671
LOINC33572-9, 34410-1
SpecimenSerum
Volume1 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time4 - 6 days
Storage / transportRoom temperature

Also known as: Extrinsic Allergic Alveolitis Profile

Test includes

Aspergillus fumigatus precipitating antibodies, IgG; Aureobasidium pullulans precipitating antibodies, IgG; Micropolyspora faeni precipitating antibodies, IgG; pigeon serum precipitating antibodies, IgG; Thermoactinomyces sacchari precipitating antibodies, IgG; Thermoactinomyces vulgaris precipitating antibodies, IgG

Use

The test is used to detect the presence of precipitating antibodies associated with hypersensitivity pneumonitis.

Methodology

Double diffusion (Ouchterlony)

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x2

Causes for rejection

Excessive hemolysis

Reference range

Normal: negative

Limitations

The presence of serum precipitins against suspected antigens indicates past exposure sufficient to elicit a humoral immunologic response but not necessarily sufficient to diagnose the disease. Moreover the specific antigen may not be represented in the testing panel. Hence, a positive test does not confirm and a negative test doesnot rule out a diagnosis of HP.

LOINC map

Result codeResult nameUnitsResult LOINC
Hypersensitivity Pneumonitis660100Micropolyspora faeni IgG34410-1
Hypersensitivity Pneumonitis660084Aureobasidium pullulans IgG33572-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86331, 86602, 86606

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation