Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Inflammatory Bowel Disease (IBD) Expanded Profile

Inflammatory Bowel Disease (IBD) Expanded Profile: Labcorp test 162045

Labcorp test 162045, CPT 83516, 86036, 86671. Specimen: Serum. Turnaround: 4 - 7 days.

Inflammatory Bowel Disease (IBD) Expanded Profile is Labcorp test code 162045, billed with CPT 83516, 86036, 86671. Specimen: Serum. Turnaround time: 4 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code162045
CPT83516(x3); 86036; 86671
LOINC47321-5, 53594-8, 53596-3, 53597-1, 77202-0
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time4 - 7 days
Storage / transportRefrigerate

Also known as: Atypical pANCA; Glycominds; IBDX

Test includes

Antichitobioside carbohydrate antibodies (ACCA); antilaminaribioside carbohydrate antibodies (ALCA); antimannobioside carbohydrate antibodies (AMCA); anti- Saccharomyces cerevisiae antibodies (gASCA); atypical perinuclear antineutrophil cytoplasmic antibody (pANCA).

Use

Aids in the diagnosis of inflammatory bowel disease (IBD) and the differential diagnosis of Crohn's disease (CD) and ulcerative colitis (UC); prognostic aid for clinical management of patients with CD.

Methodology

Enzyme immunoassay (EIA) for ACCA, ALCA, AMCA, gASCA; indirect fluorescent antibody (IFA) for atypical pANCA

Causes for rejection

Hemolysis; lipemia; heat-treated specimen; gross bacterial contamination

Reference range

When the only positive marker is pANCA, the interpretive comment on the report will read: "Suggestive of ulcerative colitis." When only one of ACCA, ALCA, AMCA, or gASCA is positive and pANCA is negative, the interpretive comment will read: "Suggestive of Crohn's disease. Pattern is not conclusive for disease behavior risk stratification." When only one of ACCA, ALCA, AMCA, or gASCA is positive and pANCA is positive, the interpretive comment will read: "Suggestive of inflammatory bowel disease. Pattern is not conclusive for any specific disease form." When any two of ACCA, ALCA, AMCA, or gASCA are positive and pANCA is positive or negative, the interpretive comment will read: "Suggestive of Crohn's disease with high risk of aggressive disease behavior (development of strictures or fistulae)." When any three or more of ACCA, ALCA, AMCA, or gASCA are positive and pANCA is positive or negative, the interpretive comment will read: "Suggestive of Crohn's disease with the very high risk of aggressive disease behavior (development of strictures or fistulae)." When all markers are negative, the interpretive comment on the report will read: "Pattern is not suggestive of inflammatory bowel disease."

Limitations

Results of this panel should be used in conjunction with clinical findings and other laboratory tests.

LOINC map

Result codeResult nameUnitsResult LOINC
gASCAunits47321-5
ACCAunits53594-8
ALCAunits53596-3
AMCAunits53597-1
IBD Expanded Panel162030Comments77202-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83516, 86036, 86671

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation