Heparin antibodies, polyspecific: Allina Health Laboratory (Abbott Northwestern) test 8775
Allina Health Laboratory (Abbott Northwestern) test 8775, CPT 86022. Specimen: Sodium citrate (Na cit) plasma. Turnaround: 1 - 2 days.
Heparin antibodies, polyspecific is Allina Health Laboratory (Abbott Northwestern) test code 8775, billed with CPT 86022. Specimen: Sodium citrate (Na cit) plasma. Turnaround time: 1 - 2 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA
24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), Labcorp, ARUP Laboratories, OHSU Laboratory Services.
Test code8775
CPT86022
LOINC—
SpecimenSodium citrate (Na cit) plasma
Volume1.5 mL
ContainerLt blue Sodium citrate (Na Cit) - 2.7mL
If the patient has a hematocrit >55, a specially prepared Lt blue Sodium citrate (NaCit) tube must be used in place of the standard Lt blue Sodium citrate (NaCit) tube.
Hematocrit-Anticoagulant adjustments
Turnaround time1 - 2 days
Same day if received by 10:30am
Also known as: HIT; HAT; Heparin induced platelet antibody
Use
This is a screening assay to aid in determining the risk for heparin induced thrombocytopenia (HIT).
Methodology
Immunoturbidimetry
Collection instructions
Do not over or under fill tube as the ratio of anticoagulant to whole blood is critical
Coag – tube fill guidelines
Immediately following collection, mix sample thoroughly by gentle inverting 8 - 10 times, to prevent clotting
Stability
Frozen (strict)
Refrigerated - NO
Causes for rejection
Specimen collected in Greiner tube(s)
Improper labeling (unlabeled or mislabeled)
Improper anticoagulant
Improperly filled tube
Hemolysis
Clotted specimen
Delay in transport
Improper storage/transport temperature
Patient on heparin > 1.0 IU/mL
Reference range
Negative
Performed
Daily: 11am
Abbreviation
PHA
Order number
LAB8775
Transport container
Microcentrifuge vial/tube in a Snap cap conical vial/tube and cap (Beaker sites)
Coagulation specimen transport vial/tube (all other sites)
Performing Laboratory
AHL - Coagulation/Special Coagulation: V
Processing instructions
Process Platelet Poor Plasma (P.P.P)
Coag – how to prepare a specimen for special coagulation testing
Transfer plasma into an aliquot tube using a spot label "NaCit Plasma P.P.P" to label as platelet poor plasma
Freeze immediately
View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29
Other tests billed with CPT 86022
- Anti-Platelet Factor 4
Cleveland Clinic LaboratoriesTest code PLATF4CPT 86022PlasmaTAT 1 day
- Heparin Antibody Assay
Michigan Medicine Laboratories (MLabs)Test code HITABCPT 86022Full 2.7 mL tube or 1 mL plasma aliquotTAT 3 hours
- Heparin-induced Platelet Antibody (HIPA)
LabcorpTest code 150075CPT 86022Serum, frozenTAT 1 - 2 days
- Heparin-induced Platelet Antibody With Reflex to Serotonin Release Assay
LabcorpTest code 150031CPT 86022Serum, frozenTAT 1 - 4 days
- Heparin-Induced Thrombocytopenia (HIT) Antibodies, PF4 IgA and IgM by ELISA
ARUP LaboratoriesTest code 2007145CPT 86022Plain red.TAT 3-7 days
- Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG
ARUP LaboratoriesTest code 2012179CPT 86022Serum separator tube.TAT 1-2 days
- Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG with Reflex to Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin
ARUP LaboratoriesTest code 2012181CPT 86022Serum separator tube.TAT 1-6 days
- HIT Antibody with Reflex to SRA Confirmation
OHSU Laboratory ServicesTest code LAB103661CPT 86022One 2.7 mL Lt Blue Na Citrate tube and one 5 mL Gold SST tube.TAT Routine: 2 Hours
- Platelet Antibody (Glycoprotein) Plasma/Eluate
ARUP LaboratoriesTest code 2007237CPT 86022, 86023Yellow (ACD solution A or B). Collect and ship same day, Sunday-Wednesday only.TAT 3-6 days
- Platelet Antibody Identification Panel
ARUP LaboratoriesTest code 3017737CPT 86022Plain red. Also acceptable: Serum separator tube (SST).TAT 7-10 days
- Platelet Antibody Profile
LabcorpTest code 117150CPT 86022SerumTAT 2 - 4 days
- Platelet Antibody Screen (Mayo)
Michigan Medicine Laboratories (MLabs)Test code MPLTNCPT 860221.5 mL serumTAT 3-5 days
- Platelet Autoantibodies
Michigan Medicine Laboratories (MLabs)Test code VPLABCPT 86022, 8602340 ml if platelet count <100,000 or 10 ml if platelet count >100,000TAT 3 - 5 days
- Platelet Dependent Antibody, Unfractionated Heparin
Cleveland Clinic LaboratoriesTest code SERORECPT 86022SerumTAT 3 - 5 days
- Platelet Surface Glycoprotein Expression (PGE) by Flow Cytometry, Whole Blood
ARUP LaboratoriesTest code 2013070CPT 86022Lavender (EDTA), pink (K2EDTA), or yellow (ACD solution B).TAT 1-3 days
- Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin
ARUP LaboratoriesTest code 2005631CPT 86022Serum separator tube.TAT 2-4 days
- Neonatal Alloimmune Thrombocytopenia (NAIT)-Initial Testing Maternal with Paternal
Michigan Medicine Laboratories (MLabs)Test code SONeonatal Alloimmune Thrombocytopenia Nait Initial Testing Maternal PaternalCPT 8602230 mL ACD-A whole blood AND 10 mL serum (2- 10 mL red top tubes) from motherTAT 10-14 days
Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation