Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG with Reflex to Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin

Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG with Reflex to Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin: ARUP Laboratories test 2012181

ARUP Laboratories test 2012181, CPT 86022. Specimen: Serum separator tube.. Turnaround: 1-6 days.

Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG with Reflex to Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin is ARUP Laboratories test code 2012181, billed with CPT 86022. Specimen: Serum separator tube.. Turnaround time: 1-6 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2012181
CPT86022; if reflexed, add 86022
LOINC73818-7
SpecimenSerum separator tube.
Turnaround time1-6 days
Storage / transportCRITICAL FROZEN. Additional specimens must be submitted when multiple tests are ordered.

Also known as: HAT; Heparin Induced Antibodies; Heparin PF4 Antibody; Heparin-Associated Antibody; HIPA; HIT Antibodies; HIT IgG, IgM, IgA; HIT PF4 Antibodies; HITA; Type II HIT

Use

Gold standard reflex testing for confirming diagnosis of HIT. Serotonin Release Assay is performed for positive HIT Antibody, IgG.

Methodology

Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA) / Qualitative Serotonin Release Assay

Collection instructions

Separate from cells ASAP or within 2 hours of collection. Transfer 5.0 mL serum to an ARUP Standard Transport Tube. (Min: 2.0 mL)

Stability

Ambient: Unacceptable; Refrigerated: 48 hours; Frozen: 2 years

Causes for rejection

Heparinized specimens

Reference range

Test Number Components Reference Interval 2012179 Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG Less than or equal to 0.399 OD 2005631 Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin Negative

Performed

Sun-Sat

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
2012180Hep-Ind Thrombocytopenia PF4 Ab, IgG73818-7

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86022

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation