Heparin-induced Platelet Antibody (HIPA): Labcorp test 150075
Labcorp test 150075, CPT 86022. Specimen: Serum, frozen. Turnaround: 1 - 2 days.
Also known as: Heparin-associated Thrombocytopenia Antibody (HATA); Heparin-induced Thrombocytopenia (HIT); Heparin-induced Thrombocytopenia Antibody (HITA); Vaccine-Associated Coagulopathy; Vaccine-Induced Immune Thrombotic Thrombocytopenia; VITT Antibody Test
Use
This test is used to assist in the diagnosis of heparin-induced thrombocytopenia.
Methodology
HIPA is measured by enzyme immunoassay (EIA) using platelet factor 4 complexed polyvinyl sulfonate (PVS) that is coated to the wells of a microtiter plate. The PVS acts like heparin, exposing antigenic sites for HIPA binding.
Collection instructions
Transfer serum to a plastic transport tube. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested .
Causes for rejection
Serum not separated from red cells; microbially contaminated, hemolyzed, lipemic, icteric, or heat-inactivated samples
Reference range
0.0−0.4 OD units
Limitations
HIPA results should not be the sole basis for establishing the diagnosis of heparin-induced thrombocytopenia. Some patients with HIPA will not develop symptoms of heparin-induced thrombocytopenia (HIT). Microbial contamination, lipemia, icterus, or hemolysis may interfere with this test and immune complexes or immunoglobulin aggregates in the patient sample can produce false-positive results. Heparin in the sample (>1 unit/mL) can produce false-negative results.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 150079 | Heparin Induced Platelet Ab | OD | 73818-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86022
- Anti-Platelet Factor 4
- Heparin Antibody Assay
- Heparin-induced Platelet Antibody With Reflex to Serotonin Release Assay
- Heparin-Induced Thrombocytopenia (HIT) Antibodies, PF4 IgA and IgM by ELISA
- Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG
- Heparin-Induced Thrombocytopenia (HIT) PF4 Antibody, IgG with Reflex to Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin
- Platelet Antibody (Glycoprotein) Plasma/Eluate
- Platelet Antibody Identification Panel
- Platelet Antibody Profile
- Platelet Antibody Screen (Mayo)
- Platelet Autoantibodies
- Platelet Dependent Antibody, Unfractionated Heparin
- Platelet Surface Glycoprotein Expression (PGE) by Flow Cytometry, Whole Blood
- Serotonin Release Assay (Heparin Dependent Platelet Antibody), Unfractionated Heparin
- Neonatal Alloimmune Thrombocytopenia (NAIT)-Initial Testing Maternal with Paternal
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation