Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Neisseria gonorrhoeae amplified RNA

Neisseria gonorrhoeae amplified RNA: Allina Health Laboratory (Abbott Northwestern) test 6745

Allina Health Laboratory (Abbott Northwestern) test 6745, CPT 87591. Specimen: Swab. Turnaround: Inpatient - 4 hours.

Neisseria gonorrhoeae amplified RNA is Allina Health Laboratory (Abbott Northwestern) test code 6745, billed with CPT 87591. Specimen: Swab. Turnaround time: Inpatient - 4 hours. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code6745
CPT87591; Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenSwab
ContainerXpert Swab Specimen Collection Kit (Allina Only, Workday # 418585) - preferred for swab collections at Allina Hospital sites or Aptima Multitest swab transport media Oral/mouth, rectal or vaginal sample collections
Turnaround timeInpatient - 4 hours Outpatient - 24 hours

Also known as: GC Probe; Neisseria gonorrhoeae; N. gonorrhoeae amplified probe; N. gonorrhoeae amplified RNA

Use

Neisseria gonorrhoeae (GC) is a common sexually transmitted infection and may be asymptomatic. N. gonorrhoeae primarily causes a lower genital tract infection, but if untreated, may cause disseminated disease or pelvic inflammatory disease with endometritis, salpingitis, pelvic peritonitis, and tubo-ovarian abscesses. This test should be ordered in patients with symptoms of cervicitis or urethritis, as well as for screening asymptomatic patients.

Methodology

Nucleic Acid Amplification Test (NAAT)

Collection instructions

If patient has had a hysterectomy, collect vaginal or urine . Vaginal specimens: Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line. Carefully insert the swab into the vagina about 2 inches past the introitus and gently rotate the swab for 10 to 30 seconds. Make sure the swab touches the walls of the vagina so that moisture is absorbed by the swab and then withdraw the swab without touching the skin. While holding the swab in the same hand, unscrew the cap from the tube. Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Aptima Multitest Swab Specimen Collection Kit. Immediately place the swab into the transport tube so that the score line is at the top of the tube. Carefully break the swab shaft at the score line against the side of the tube. Immediately discard the top portion of the swab shaft. Tightly screw the cap onto the tube. Rectal Specimens : Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line. Carefully insert the swab into the rectum about 1-2 inches (3-5 cm) past the anal margin and gently rotate the swab for 5 to 10 seconds. Withdraw the swab without touching the skin. While holding the swab in the same hand, unscrew the cap from the tube. Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Aptima Multitest Swab Specimen Collection Kit. Immediately place the swab into the transport tube so that the score line is at the top of the tube. Carefully break the swab shaft at the score line against the side of the tube. Immediately discard the top portion of the swab shaft. Tightly screw the cap onto the tube. Oral Specimens: Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new A

Stability

Swab: Ambient (preferred) - 60 days Refrigerated - 60 days Frozen - NO Urine: Ambient (preferred) - 30 days Refrigerated - 30 days Frozen - NO Specimen retention time: One (1) week

Patient preparation

Urine collections: Patient should not have urinated for at least 1 hour prior to specimen collection. Female patients should not cleanse labial area prior to providing the specimen

Causes for rejection

Collection from vaginal cuff source Midstream or clean catch urine Urine collected for chemistry testing or cultures cannot be used for GC or Chlamydia PCR testing Urine transport tube not filled to “Fill area” (above or below – rejected) Frozen specimens Sources other than oral, rectal, vaginal, or voided urine Improper label (unlabeled or mislabeled) Time delay between time of collection and receipt of specimen Improper transport container Improper transport temperature Interfering substances Inappropriate specimen type Leaking container

Reference range

Negative (Not Detected)

Performed

Daily

Abbreviation

GCP

Order number

87591.0

Alternate container

Screw cap plastic container (sterile) Alternate collection instructions: Direct patient to provide first-catch urine (approximately 20 to 30 mL of initial urine stream) into urine collection cup free of any preservatives. The cup should be removed from the urine stream when 20-30 mL of urine is in the cup. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity and should not be sent for testing. Alternate processing instructions: Urine should preferably be transferred to urine specimen transport at the bedside to reduce risk of molecular cross contamination. If poured off in the lab change gloves before and after opening urine. Label urine transport with patient information. Remove cap from urine specimen transport tube and transfer urine into urine specimen transport tube using disposable pipette provided. The correct volume of urine has been added when fluid level is between black fill lines on transport tube. Screw cap on tightly to prevent leaking. Alternate transport container: Xpert Urine Specimen Collection Kit (Allina Only, Workday # 418586) - preferred for urine collections at Allina Hospital sites or Aptima urine specimen collection kiit

Alternate specimens

Urine, voided (Female/Male) For other sources, see GC culture; Chlamydia trachomatis, misc sources

Transport container

Xpert Swab Specimen Collection Kit or Aptima Multitest swab specimen collection kit

Performing Laboratory

AHL - Microbiology: M

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 87591

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.