Allina Health Laboratory (Abbott Northwestern) test 2332, CPT 86359, 86360. Specimen: EDTA whole blood. Turnaround: 2 days.

CD4/CD8 T cells panel is Allina Health Laboratory (Abbott Northwestern) test code 2332, billed with CPT 86359, 86360. Specimen: EDTA whole blood. Turnaround time: 2 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code2332
CPT86360; 86359
LOINC—
SpecimenEDTA whole blood
Volume4.0 mL
Minimum volume3.0 mL
ContainerLavender (EDTA), 4mL
Turnaround time2 days

Also known as: T-helper suppressor; T-cell subset; TCD4; CD4 Count for Immune Monitoring, Blood; LAB15125; 15125; Mayo Clinical Laboratories (15125): R-NX

Use

Monitor CD4 levels for HIV positive patients Limitations: No pathologist morphology or interpretation is included with this assay

Methodology

Flow Cytometry

Collection instructions

Immediately following collection, mix sample thoroughly by gently inverting 8 - 10, times to prevent clotting

Stability

Ambient - 72 hours Specimen must be received at the Central Laboratory within 72 hrs of collection.

Causes for rejection

Improper label (unlabeled or mislabeled) Wrong container (anticoagulant or solution) Improper blood/anticoagulant ratio Delay in transport Improper storage Inappropriate timing of collection Interfering substances Leaking container

Reference range

Component 1 - 7 days 7 day s - 12 mo 12 mo – 5 yrs >5 yrs CD3 (%) 72 - 86 65 - 73 64 – 74 57 - 83 CD4 (%) 57 - 70 31 - 59 39 - 49 32 - 63 CD8 (%) 14 - 26 14 - 24 17 - 31 9 - 39 CD3 absolute (/cumm) 1300 - 6500 1300 - 7100 1100 - 5000 840 - 2641 CD4 absolute (/cumm) 1000 - 5500 1200 - 4500 800 - 3000 488 - 1711 CD8 absolute (/cumm) 400 - 1700 500 - 2000 500 - 2700 154 - 1097

Performed

Mo - Fr

Abbreviation

CD4

Order number

LAB2332

Transport container

Lavender (EDTA), 4mL

Performing Laboratory

AHL - Flow Cytometry: F

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86359, 86360

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation