T-Lymphocyte Helper/Suppressor Profile: Labcorp test 096925
Labcorp test 096925, CPT 86359, 86360. Specimen: Whole blood. Turnaround: 1 - 3 days.
Also known as: Helper:Suppressor Ratio; T4:T8 Analysis
Test includes
This test includes absolute CD4 helper/inducer T cells (CD3CD4); absolute CD8 suppressor/cytotoxic T cells (CD3CD8); absolute lymphocyte count; absolute T cells (CD3); CD4:CD8 ratio; CBC with differential and platelet count.
Methodology
Flow cytometry
Collection instructions
Immediately invert the tube eight to 10 times after collection. To maintain cellular viability, collect the specimen in either a yellow-top tube (ACD-A or ACD-B) for arrival at the laboratory within 48 hours of collection, or a lavender-top (EDTA) tube for arrival at the laboratory within 24 hours of collection. Record the date and time of venipuncture on both the tube(s) and the test requisition form.
Stability
| Temperature | Period |
|---|---|
| Room temperature | Yellow-top (ACD-A) or (ACD-B) tube: 2 days |
| Lavender-top (EDTA) tube: 1 day | Refrigerated |
| Unstable | Frozen |
| Unstable | Freeze/thaw cycles |
Causes for rejection
Hemolysis; specimen refrigerated or frozen; clotted specimen; contaminated specimen
Reference range
Reference intervals for adults have been established by the laboratory. See table. Reference Intervals for Lymphocyte Immunophenotyping CD Age 95% Confidence Interval Percentage Cells/mm³ Minimum Maximum Minimum Maximum Pediatric reference intervals are from Comans-Bitter WM, de Groot R, van den Beemd R, et al. Immunophenotyping of blood lymphocytes in childhood. Reference values for lymphocyte subpopulations. J Pediatrics. 1997 Mar; 130(3):388-393. CD3 Neonates 1 wk to 2 m 2 to 5 m 5 to 9 m 9 to 15 m 15 to 24 m 2 to 5 y 5 to 10 y 10 to 16 y Adults CD3CD4 Neonates 1 wk to 2 m 2 to 5 m 5 to 9 m 9 to 15 m 15 to 24 m 2 to 5 y 5 to 10 y 10 to 16 y Adults CD3CD8 Neonates 1 wk to 2 m 2 to 5 m 5 to 9 m 9 to 15 m 15 to 24 m 2 to 5 y 5 to 10 y 10 to 16 y Adults T4:T8 ratio Adults 0.92 3.72
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 059603 | Absolute CD 3 | /uL | 8122-4 |
| 505010 | Absolute CD 4 Helper | /uL | 24467-3 |
| 505579 | Abs. CD 8 Suppressor | /uL | 14135-8 |
| 059618 | % CD 3 Pos. Lymph. | % | 8124-0 |
| 505009 | % CD 4 Pos. Lymph. | % | 8123-2 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86359, 86360
- CD4 Absolute Count
- Helper/Suppressor and Natural Killer Cell Profile
- Immune Deficiency Profile VIII
- Immunodeficiency (CDC) Panel
- Immunodeficiency Basic Panel
- Lymphocyte Activity Profile
- Lymphocyte Subset Panel 3 - T-Cell Subsets (CD4 and CD8), Absolute Counts Only
- Lymphocyte Subset Panel 4 - T-Cell Subsets Percent and Absolute, Whole Blood
- Lymphocyte Subset Panel 5 - Total Lymphocyte Enumeration
- Lymphocyte Subset Panel 6 - Total Lymphocyte Enumeration with CD45RA and CD45RO
- Lymphocyte Subset Panel 7 - Congenital Immunodeficiencies
- Lymphoma Full Consult
- Natural Killer Cell and Activated T-Cell Profile/IL-2r
- Natural Killer Cell and Natural Killer T-Cell Panel
- T- and B-Lymphocyte and Natural Killer Cell Profile
- T- and B-Lymphocyte Differential Profile
- T-Cell Activation Profile, CD8 Subsets
- T-Lymph Markers and NK
- CD4:CD8 Ratio Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation