Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › BAL CD4/CD8

BAL CD4/CD8: Allina Health Laboratory (Abbott Northwestern) test 12402

Allina Health Laboratory (Abbott Northwestern) test 12402, CPT 88184, 88185. Specimen: Bronchoalveolar lavage (BAL). Turnaround: 48 hrs.

BAL CD4/CD8 is Allina Health Laboratory (Abbott Northwestern) test code 12402, billed with CPT 88184, 88185. Specimen: Bronchoalveolar lavage (BAL). Turnaround time: 48 hrs. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services, ARUP Laboratories, Quest Diagnostics, Cleveland Clinic Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code12402
CPT88184; 88185 x 3
LOINC—
SpecimenBronchoalveolar lavage (BAL)
Volume10 mL
Minimum volume1 mL
ContainerSterile vial/container
Turnaround time48 hrs

Also known as: BAL; Bronchoalveolar lavage T cell subsets; Tests included:; Tubes and Markers; Tube: BAL; Markers: CD3, CD4, CD8 and CD45

Use

Monitor T-cell subsets in Bronchoalveolar lavage (BAL) specimens Limitations: No pathologist interpretation will be included with this assay

Methodology

Flow Cytometry

Stability

Refrigerate

Causes for rejection

Improper label (unlabeled or mislabeled) Wrong container (anticoagulant or solution) Delay in transport Improper storage Interfering substances Leaking container

Performed

Mo - Fr

Abbreviation

BAL CD4/CD8

Order number

LAB12402

Transport container

Falcon vial/tube - 15mL Alternate transport container: 50mL sterile conical tube

Performing Laboratory

AHL - Flow Cytometry: F

Processing instructions

Place bronchoalveolar lavage fluid in a sterile vial/container (Falcon vial/tube - 50mL conical tube or other sterile screw capped container. Leave in its own fluid (do not add anti-coagulant) and do not spin

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88184, 88185

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation