Quest Diagnostics test 94719, CPT 81235. Specimen: Formalin-fixed, paraffin-embedded tissue.

Epidermal Growth Factor Receptor (EGFR) Mutation, Cobas V2, Solid Tumor is Quest Diagnostics test code 94719, billed with CPT 81235. Specimen: Formalin-fixed, paraffin-embedded tissue. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code94719
CPT81235
LOINC—
SpecimenFormalin-fixed, paraffin-embedded tissue
Minimum volume5 unstained slides AND 1 H&E slide
ContainerFormalin-fixed, paraffin-embedded tissue block
Storage / transportRoom temperature

Also known as: Tarceva; T790M; EGFR; Tagrisso; erlotinib; NSCLC; osimertinib

Methodology

Real-Time Polymerase Chain Reaction

Collection instructions

Only NSCLC FFPET sections of 5-micron thickness containing at least 10% tumor content by area are to be used in the Cobas® EGFR Test. Any sample containing less than 10% tumor content by area should be macro-dissected after deparaffinization.

Stability

Formalin-fixed, paraffin-embedded tissue Room temperature: 1 year Refrigerated: Unacceptable Frozen: Unacceptable 5 Micron unstained slides Room temperature: 60 days Refrigerated: Unacceptable Frozen: Unacceptable

Causes for rejection

Baked slides

Reference range

Not detected

Alternative specimen(s)

10 unstained 5-micron slides AND 1 H&E slide

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81235

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation