EGFR Hotspot PCR Analysis Assay: Cleveland Clinic Laboratories test EGFRID
Cleveland Clinic Laboratories test EGFRID, CPT 81235. Specimen: Block, Formalin fixed paraffin. Turnaround: 3 days.
Also known as: EGFR; EGFRGN
Methodology
Real-Time Polymerase Chain Reaction (RT-PCR)
Stability
| Temperature | Period |
|---|---|
| Ambient | FFPET slides and scrolls, cell block slides and alcohol fixed slides are stable at ambient temperature indefinitely. |
| Refrigerated | FFPET slides and scrolls, cell block slides and alcohol fixed slides are stable at ambient temperature indefinitely. |
| Frozen | Unacceptable |
Special instructions
Formalin-fixed paraffin-embedded tissue slides. Transport and store slides at ambient temperature. Three unstained sections FFPE tissue on charged, unbaked slides or scrolls, plus one H&E stained section with best tumor area circled by a pathologist. Provide the percentage of tumor cells present, minimum 10%. Specimens that undergo heavy metal fixation or are decalcified with strong acids (i.e., formic acid) are not acceptable for molecular testing. Non-decalcified specimens or samples that undergo EDTA decalcification are acceptable.
Performed
Mon - Fri
Collect Temperature
Ambient
Performing Laboratory
Cleveland Clinic Laboratories
View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 81235
- EGFR Mutation Analysis, Cell Pellet
- EGFR Mutation by NGS
- NRAS-BRAF-EGFR S492R Hotspot PCR Analysis Assay
- Point of Care- Basic Metabolic Panel Plus, i-Stat
Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.