Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Donor, Stem Cells Donor Panel

Donor, Stem Cells Donor Panel: Quest Diagnostics test 93309

Quest Diagnostics test 93309, CPT 86644, 86703, 86704, 86780, 86790, 86803, 87340, 87798, 87801. Specimen: 6 mL serum collected in each of two separate tubes and.

Donor, Stem Cells Donor Panel is Quest Diagnostics test code 93309, billed with CPT 86644, 86703, 86704, 86780, 86790, 86803, 87340, 87798, 87801. Specimen: 6 mL serum collected in each of two separate tubes and. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Allina Health Laboratory (Abbott Northwestern), ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code93309
CPT86703, 87340, 86704, 86803, 86790, 86644, 87801, 87798, 86780
LOINC—
Specimen6 mL serum collected in each of two separate tubes and 6 mL plasma collected in each of two separate EDTA (lavender-top) tubes
Minimum volume6 mL serum • 6 mL plasma
ContainerSee Collection Instructions
Storage / transportRefrigerated (cold packs)

Methodology

Immunoassay (IA) • Hemagglutination • Nucleic Acid Amplification

Collection instructions

Label the tubes according to your standard operating procedure, making sure that each tube has at least two unique patient identifiers. If transport temperature will be frozen, centrifuge the red/lavender-top tube and transfer the serum/plasma into a plastic screw-cap vial. The plastic screw-cap vial (aliquot tube) containing serum or plasma must be labeled with the specimen type (serum or plasma) and at least two unique patient identifiers. Aliquot tubes must be processed and labeled at the original collection site. If aliquot tubes are submitted, do not send the original red/lavender-top tube. NOTE: Please include serum, red-top (no gel) for CMV portion of testing. Please note: This test is to be used for the screening of DONORS of human cells, tissues, and cellular and tissue-based products for infectious diseases. For Shipper collection please see detailed instructions in Test Resources.

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated5 days
Frozen28 days

Causes for rejection

Sample not marked serum/plasma • CMV samples submitted in gel tubes (serum separator tube - SST)

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86644, 86703, 86704

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation