Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › PCB Panel, Congeners, Serum/Plasma
PCB Panel, Congeners, Serum/Plasma: Quest Diagnostics test 93277
Quest Diagnostics test 93277, CPT 82441. Specimen: 2 mL serum collected in a red-top tube (no gel).
PCB Panel, Congeners, Serum/Plasma is Quest Diagnostics test code 93277, billed with CPT 82441. Specimen: 2 mL serum collected in a red-top tube (no gel). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code93277
CPT82441
LOINC—
Specimen2 mL serum collected in a red-top tube (no gel)
Minimum volume0.7 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)
Methodology
Gas Chromotography/Tandem Mass Spectrometry (GC/MS/MS)
Collection instructions
Promptly centrifuge and separate serum or plasma into a polypropylene plastic transport tube
Stability
| Temperature | Period |
|---|---|
| Room temperature | 48 hours |
| Refrigerated | 14 days |
| Frozen | 12 months |
Causes for rejection
Received room temperature • Serum separator tube (SST) • Polymer gel separation tube
Reference range
See Laboratory Report
Alternative specimen(s)
Plasma
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 82441
- Methylene Chloride, Whole Blood
- Polychlorinated Biphenyls (PCB) Congeners, Screen and Confirmation
- Polychlorinated Biphenyls (PCB) Panel, Congeners, Serum or Plasma
- Polychlorinated Biphenyls (PCB) Panel, Congeners, Serum or Plasma
- Solvent Inhalants Profile, Urine Metabolites
- Tetrachloroethylene, Occupational Exposure, Whole Blood
- Polychlorinated Biphenyls (Congeners/Aroclors )
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation