Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Polychlorinated Biphenyls (PCB) Congeners, Screen and Confirmation

Polychlorinated Biphenyls (PCB) Congeners, Screen and Confirmation: Labcorp test 790890

Labcorp test 790890, CPT 82441. Specimen: Serum. Turnaround: 3 - 14 days.

Polychlorinated Biphenyls (PCB) Congeners, Screen and Confirmation is Labcorp test code 790890, billed with CPT 82441. Specimen: Serum. Turnaround time: 3 - 14 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code790890
CPT82441
LOINC—
SpecimenSerum
Volume5 mL
Minimum volume1 mL
ContainerRed-top tube (do not use gel-barrier tubes)
Turnaround time3 - 14 days
Storage / transportSubmission/transport (<3 days): Room temperature. For storage beyond three days, specimen should be refrigerated or frozen.

Also known as: Aroclors

Methodology

Initial presumptive testing by gas chromatography/mass spectrometry (GC/MS) at a testing threshold of 0.5 ng/mL; presumptive positives confirmed by definitive gas chromatography/mass spectrometry (GC/MS) at a testing threshold of 0.5 ng/mL

Collection instructions

Serum or plasma should be separated from cells within two hours of venipuncture. Submit serum or plasma in a plastic transport tube.

Causes for rejection

Gel-barrier tubes

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82441

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation