Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › HPV mRNA E6/E7, Rectal

HPV mRNA E6/E7, Rectal: Quest Diagnostics test 91932

Quest Diagnostics test 91932, CPT 87624. Specimen: Anal/rectal specimen collected using a dacron/polyester swab or anal/rectal brush and submitted in 3 mL Preservcyt® tran.

HPV mRNA E6/E7, Rectal is Quest Diagnostics test code 91932, billed with CPT 87624. Specimen: Anal/rectal specimen collected using a dacron/polyester swab or anal/rectal brush and submitted in 3 mL Preservcyt® transport medium ThinPre. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, OHSU Laboratory Services, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code91932
CPT87624
LOINC—
SpecimenAnal/rectal specimen collected using a dacron/polyester swab or anal/rectal brush and submitted in 3 mL Preservcyt® transport medium ThinPrep® vial or Aptima® specimen transfer tube (green label)
Minimum volume1.5 mL
ContainerLiquid cytology PreservCyt® (ThinPrep®) vial
Storage / transportRoom temperature

Also known as: Human Papillomavirus

Methodology

Transcription-Mediated Amplification (TMA)

Collection instructions

To collect an anal-rectal sample, a wetted, non-lubricated Dacron/Polyester swab is used. The Dacron/Polyester swab is inserted about 3 cm (or until resistance is met) into the anal canal past the anal verge, into the rectal vault. This is done without visualization of the anal canal. Firm lateral pressure is applied to the swab handle as it is rotated and slowly moved in and out. Slowly withdraw swab from the anal canal. Swish the swab vigorously in PreservCyt® fluid in the ThinPrep® vial. Discard the swab. Cap and tighten the ThinPrep® vial. Follow the same procedure if using a brush to collect an anal-rectal sample. Avoid using cotton swab on a wooden stick because the handle may break and splinter during collection. Swab that is grossly contaminated with feces should be discarded and the collection repeated.

Stability

TemperaturePeriod
Room temperature30 days
Refrigerated30 days
FrozenNot established

Causes for rejection

Digene® vials • SurePath™ vials

Reference range

Not detected

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

The analytical performance characteristics of this assay have been determined by Quest Diagnostics. The modifications have not been cleared or approved by the FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87624

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation