Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Human Papillomavirus (HPV) High Risk Screen, by Transcription-Mediated Amplification (TMA), ThinPrep

Human Papillomavirus (HPV) High Risk Screen, by Transcription-Mediated Amplification (TMA), ThinPrep: ARUP Laboratories test 3016943

ARUP Laboratories test 3016943, CPT 87624. Specimen: Cervical, anal, or vaginal specimen with brush or spatula from ThinPrep kit and place in PreservCyt Media. Turnaround: 1-5 days.

Human Papillomavirus (HPV) High Risk Screen, by Transcription-Mediated Amplification (TMA), ThinPrep is ARUP Laboratories test code 3016943, billed with CPT 87624. Specimen: Cervical, anal, or vaginal specimen with brush or spatula from ThinPrep kit and place in PreservCyt Media. Turnaround time: 1-5 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3016943
CPT87624
LOINC31208-2, 49896-4
SpecimenCervical, anal, or vaginal specimen with brush or spatula from ThinPrep kit and place in PreservCyt Media
Turnaround time1-5 days
Storage / transportRefrigerated

Also known as: HPV HR E6/E7 TMA; HPV RNA; Nucleic Acid Amplification Test (NAAT) HPV PCR, HPV TMA

Use

FDA-approved test for routine cervical cancer screening in combination with cervical cytology (pap smear) in individuals 30 years or older with a cervix. FDA approved test for HPV primary screening of individuals 25 years of age or older with a cervix. Follow-up test for abnormal cytology results in individuals 21 years or older with a cervix. HPV testing is not recommended in individuals <21 years of age. Routine cervical cancer screening, which includes cytology (PAP test), should begin at age 21. For patient 21-29 years, Pap tests are the primary screening method, and HPV testing is typically only used if the Pap test is abnormal.

Methodology

Qualitative Nucleic Acid Amplification Test (NAAT)

Collection instructions

Transport original ThinPrep or briefly vortex and transfer 1 mL to an Aptima Specimen Transfer Tube (ARUP supply # 42711 ). Available online through eSupply using ARUP Connect (TM) or contact ARUP Client Services at 800-522-2787. To reduce the potential for contamination, ThinPrep specimens should be poured off, using sterile technique, into the Aptima Specimen Transfer Tube prior to cytology testing.

Stability

Ambient: 1 month; Refrigerated: 105 days; Frozen: Unacceptable

Patient preparation

Females should avoid high concentrations of antifungal cream or contraceptive jelly, and should not douche prior to time of collection.

Causes for rejection

Bloody or dark brown specimens. Specimens in any media other than indicated above.

Remarks

Specimen source required.

Performed

Sun-Sat

Compliance Category

Depends on Specimen/Source/Method

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0060752HPV Source31208-2
2007891HPV, High Risk by TMA49896-4

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 87624

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation