Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › KIT D816 Mutation Analysis (Mastocytosis)

KIT D816 Mutation Analysis (Mastocytosis): Quest Diagnostics test 91772

Quest Diagnostics test 91772, CPT 81273. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube.

KIT D816 Mutation Analysis (Mastocytosis) is Quest Diagnostics test code 91772, billed with CPT 81273. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code91772
CPT81273
LOINC—
Specimen5 mL whole blood collected in an EDTA (lavender-top) tube
Minimum volume2 mL whole blood • 0.5 mL bone marrow • 6 slides
ContainerEDTA (lavender-top) tube
Storage / transportRoom temperature

Methodology

Next Generation Sequencing

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
FrozenUnacceptable

Causes for rejection

Received frozen

Reference range

Not detected

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Whole blood collected in: Sodium heparin (green-top) or ACD-B (yellow-top) tube • 2 mL bone marrow aspirate collected in an EDTA (lavender-top) tube • Formalin-fixed, paraffin-embedded tissue block • 10 slides tissue submitted in a slide holder

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81273

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation