Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › KIT D816V Mutation

KIT D816V Mutation: Michigan Medicine Laboratories (MLabs) test D816V

Michigan Medicine Laboratories (MLabs) test D816V, CPT 81273. Specimen: 5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI; Formalin-fixed, paraffin. Turnaround: 2 - 7 days.

KIT D816V Mutation is Michigan Medicine Laboratories (MLabs) test code D816V, billed with CPT 81273. Specimen: 5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI; Formalin-fixed, paraffin-embedded tissue (pr. Turnaround time: 2 - 7 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeD816V
CPT81273
LOINC—
Specimen5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI; Formalin-fixed, paraffin-embedded tissue (preferably not decalcified); Fixed cytogenetic cell suspensions or pellets in Carnoy’s fixative. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Volume5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI; Formalin-fixed, paraffin-embedded tissue (preferably not decalcified); Fixed cytogenetic cell suspensions or pellets in Carnoy’s fixative. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time2 - 7 days

Also known as: Systemic Mastocytosis; KIT c.2447A>T (D816V) Mutation; c-KIT Mutation; KIT Asp816Val Mutation Analysis

Use

This test is used for qualitative detection of the KIT c.2447A>T (D816V) mutation found in most adults (>80%) with systemic mastocytosis. Detection of the KIT D816V mutation can aid in diagnosis of systemic mastocytosis and guide choice of therapy since it is associated with resistance to imatinib mesylate. The KIT D816V mutation also occurs in some cases of acute myelogenous leukemia and seminoma. This test is not intended to detect minimal residual disease.

Collection instructions

Collect blood or bone marrow in a lavender top tube. Refrigerate and send intact blood or bone marrow specimen within 48 hours of collection. Fresh cell suspensions in RPMI should be refrigerated and sent, preferably within 48 hours. Frozen cell suspensions – preferably frozen with 1 hour of collection – may also be sent frozen on dry ice. Fixed cytogenetic cell suspensions or pellets in Carnoy’s fixative. Refrigerate and send. For formalin-fixed, paraffin-embedded tissue, a block containing the high percentage of neoplastic cells is preferred. Unstained, UNBAKED slides (5-8, 10-micron slides; 10-15 if few neoplastic cells are present) with associated H&E stained slide are also acceptable. Decalcified tissue or other fixatives will be accepted and the assay attempted, however these may result in failed testing due to degraded nucleic acid. Both blocks and slides should be stored at room temperature.

Reference range

Interpretive report provided.

Limitations

The limit of detection of this assay is 1% mutation-bearing cells. Mutations may not be detected in samples with a neoplastic burden below this level. Mutations other than KIT D616V will not be detected by this assay.

Section

Molecular Diagnostics

Performed

Monday - Friday

NY State approved

No

Alternate specimens

The preferred specimen is whole blood or bone marrow collected in EDTA (lavender top). However, ACD (yellow top) and heparin (green top) may also be accepted. Previously extracted DNA may also be accepted.

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81273

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation