Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Cardio IQ® Fibrinogen Antigen, Nephelometry
Cardio IQ® Fibrinogen Antigen, Nephelometry: Quest Diagnostics test 91743
Quest Diagnostics test 91743, CPT 85385. Specimen: 1 mL plasma collected in 3.2% sodium citrate (light blue-top) tube.
Cardio IQ® Fibrinogen Antigen, Nephelometry is Quest Diagnostics test code 91743, billed with CPT 85385. Specimen: 1 mL plasma collected in 3.2% sodium citrate (light blue-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code91743
CPT85385
LOINC—
Specimen1 mL plasma collected in 3.2% sodium citrate (light blue-top) tube
Minimum volume0.5 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)
Also known as: CardioIQ®; Fibrinogen Antigen; Cardio IQ®
Methodology
Nephelometry
Stability
| Temperature | Period |
|---|---|
| Room temperature | Unacceptable |
| Refrigerated | 8 days |
| Frozen | 90 days |
Patient preparation
Overnight fasting is required
Causes for rejection
Hemolysis • Lipemia
Reference range
180-350 mg/dL
Notices
CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 85385
- Fibrinogen Antigen
- Fibrinogen Antigen
- Fibrinogen Antigen
- Fibrinogen Antigen
- Fibrinogen Evaluation Profile
- Fibrinogen Panel
- Prolonged Clot Time Reflexive Profile
- Thrombotic Risk Profile
- Thrombotic Risk Profile
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation