Fibrinogen Antigen: Labcorp test 117052
Labcorp test 117052, CPT 85385. Specimen: Plasma, frozen. Turnaround: 3 - 5 days.
Also known as: Factor I Antigen; Fibrinogen Level
Use
Diagnosis of homozygous and heterozygous fibrinogen deficiency as well as dysfibrinogenemia, diagnosis of disseminated intravascular coagulation and fibrinogen levels can be used to assess the effectiveness of thrombolytic therapy.
Methodology
Immunonephelometry
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When non-citrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and re-centrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Causes for rejection
EDTA plasma specimen; serum specimen; microbially contaminated samples; hemolysis; gross lipemia that cannot be cleared by ultracentrifugation; improper sample type; sample out of stability
Reference range
See table. Age Male (mg/dL) Female (mg/dL) 0 to 1 y 116−349 116−349 2 to 5 y 176−354 189−395 6 to 17 y 191−416 191−416 18 to 50 y 206−478 206−478 >50 y 233−496 233−496
Limitations
Fibrinogen is an acute-phase reactant and can often become significantly increased in conditions involving tissue damage, infection, or inflammation. Increased levels may be seen in smokers, during pregnancy, and in women taking oral contraceptives. Fibrinogen levels can be diminished in advanced liver disease. Very high levels of heparin, direct thrombin inhibitors, or fibrin breakdown products may falsely reduce fibrinogen levels because they interfere with the rate of clot formation. Lipemia or hemolysis may interfere with this assay.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 117051 | Fibrinogen Antigen | mg/dL | 42772-4 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85385
- Fibrinogen Antigen
- Fibrinogen Antigen
- Fibrinogen Antigen
- Fibrinogen Evaluation Profile
- Fibrinogen Panel
- Prolonged Clot Time Reflexive Profile
- Thrombotic Risk Profile
- Thrombotic Risk Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation