Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Hemophilia A (Factor VIII) Inversions

Hemophilia A (Factor VIII) Inversions: Quest Diagnostics test 90828

Quest Diagnostics test 90828, CPT 81403. Specimen: 4 mL whole blood collected in an EDTA (lavender-top) tube.

Hemophilia A (Factor VIII) Inversions is Quest Diagnostics test code 90828, billed with CPT 81403. Specimen: 4 mL whole blood collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, OHSU Laboratory Services, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code90828
CPT81403
LOINC—
Specimen4 mL whole blood collected in an EDTA (lavender-top) tube
Minimum volume2 mL whole blood • 10 mL amniotic fluid • 10 mg chorionic villi
ContainerEDTA (lavender-top) tube
Storage / transportRoom temperature Specimen stability ⁠⁠⁠⁠⁠⁠⁠Whole blood Room temperature: 8 days Refrigerated: 8 days Frozen: Unacceptable Amniotic fluid, chorionic villi, cultured cells Room temperature: 48 hours Refrigerated: Unacceptable Frozen: Unacceptable

Also known as: F8 Intron 1 Inversion; F8 Intron 22 Inversion; F8 Gene Inversions

Methodology

Capillary Electrophoresis • Inverse Polymerase Chain Reaction

Collection instructions

Do not hold specimen; forward to laboratory when specimen arrives. Whole blood: Specimen stability is crucial. Store and ship room temperature immediately. Do not freeze. For fetal testing: 1. Please call 1-866-GENE-INFO (1-866-436-3463) prior to submission. 2. Documentation of parental carrier status must be provided. 3. It is required that Maternal Cell Contamination Study, STR Analysis be ordered in conjunction with fetal testing. A separate tube of maternal blood (EDTA) is required for this test. Amniotic fluid: Normal collection procedure. Specimen stability is crucial. Store and ship at room temperature immediately. Do not refrigerate or freeze; forward to laboratory when sample arrives. Amniocyte or chorionic villus (CVS) culture: Two sterile T-25 flasks, 75% confluent, filled with culture medium. Specimen stability is crucial. Store and ship at room temperature immediately. Do not refrigerate or freeze; forward to laboratory when cells arrive. Dissected chorionic villus (CVS) biopsy: 10-20 mg dissected chorionic villi collected in sterile tube, filled with sterile culture medium. Specimen stability is crucial. Store and ship at room temperature immediately. Do not refrigerate or freeze; forward to laboratory when sample arrives.

Causes for rejection

Do not reject

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Whole blood collected in: Sodium heparin (green-top) tube or ACD (yellow-top) tube • 10 mL amniotic fluid collected in a sterile plastic leak-proof container • 10 mg chorionic villi collected in a sterile tube filled with sterile culture media • Cultured cells collected in each of two separate sterile T-25 flasks, 75% confluent

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81403

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation