Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Hemophilia A ( F8 ) 2 Inversions with Reflex to Sequencing and Reflex to Deletion/Duplication

Hemophilia A ( F8 ) 2 Inversions with Reflex to Sequencing and Reflex to Deletion/Duplication: ARUP Laboratories test 3004232

ARUP Laboratories test 3004232, CPT 81403, 81406, 81407. Specimen: Lavender or pink (EDTA) or yellow (ACD solution A or B).. Turnaround: 7-42 days.

Hemophilia A ( F8 ) 2 Inversions with Reflex to Sequencing and Reflex to Deletion/Duplication is ARUP Laboratories test code 3004232, billed with CPT 81403, 81406, 81407. Specimen: Lavender or pink (EDTA) or yellow (ACD solution A or B).. Turnaround time: 7-42 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3004232
CPT81403; if reflexed to NGS, add 81407; if reflexed to Del/Dup, add 81406
LOINC66746-9, 82939-0
SpecimenLavender or pink (EDTA) or yellow (ACD solution A or B).
Turnaround time7-42 days Reported within 14 days if not reflexed.
Storage / transportRefrigerated.

Also known as: DNA analysis for F8 deficiency; DNA analysis for hemophilia A; factor VIII genetic analysis; hemophilia A carrier screening; hemophilia A carrier status; Hemophilia A molecular cascade; hemophilia A mutation evaluation; hemophilia A reflex panel; severe hemophilia A comprehensive reflex panel

Use

Use to detect causal F8 variant in individuals with severe hemophilia A or to determine carrier status for at-risk females with severely affected male relatives. For mild to moderate hemophilia A, Hemophilia A ( F8 ) Sequencing ( 3004241 ) is preferred.

Methodology

Inverse Polymerase Chain Reaction / Massively Parallel Sequencing / Multiplex Ligation-Dependent Probe Amplification (MLPA)

Collection instructions

Transport 3 mL whole blood. (Min: 3 mL)

Stability

Ambient: 72 hours; Refrigerated: 1 week; Frozen: Unacceptable

Causes for rejection

Serum or plasma; grossly hemolyzed or frozen specimens. Saliva. Buccal brush or swab, FFPE tissue, DNA.

Reference range

Refer to report

Performed

Varies

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is not New York state approved. The performing laboratory will submit an NYDOH Single Use Permit (SUP) upon receipt of order. If SUP is approved by NYDOH, testing will be performed.

LOINC map

Result codeResult nameUnitsResult LOINC
2001617F8 COMP Specimen66746-9
3004236Hemophilia A (F8) Interpretation82939-0

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 81403, 81406, 81407

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation