Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Yo Antibody Screen with Reflex to Titer and Western Blot, CSF

Yo Antibody Screen with Reflex to Titer and Western Blot, CSF: Quest Diagnostics test 90117

Quest Diagnostics test 90117, CPT 86255. Specimen: 0.8 mL CSF.

Yo Antibody Screen with Reflex to Titer and Western Blot, CSF is Quest Diagnostics test code 90117, billed with CPT 86255. Specimen: 0.8 mL CSF. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code90117
CPT86255
LOINC—
Specimen0.8 mL CSF
Minimum volume0.5 mL
ContainerSterile screw-cap vial
Storage / transportRefrigerated (cold packs)

Also known as: Neuronal Nuclear (Yo) Antibody; Purkinje Cell

Methodology

Immunofluorescence Assay (IFA)

Stability

TemperaturePeriod
Room temperature8 hours
Refrigerated7 days
Frozen6 months

Patient preparation

Overnight fasting is preferred

Causes for rejection

Received room temperature

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86255

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation