Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Anti-N-methyl-D-Aspartate Receptor (NMDAR), Serum

Anti-N-methyl-D-Aspartate Receptor (NMDAR), Serum: Labcorp test 505375

Labcorp test 505375, CPT 86255. Specimen: Serum. Turnaround: 3 - 5 days.

Anti-N-methyl-D-Aspartate Receptor (NMDAR), Serum is Labcorp test code 505375, billed with CPT 86255. Specimen: Serum. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code505375
CPT86255
LOINC93870-4
SpecimenSerum
Volume2 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerSerum from a gel-barrier tube, serum from a red-top tube, gel-barrier tube, serum transfer tube
Turnaround time3 - 5 days
Storage / transportRoom temperature

Use

NMDAR1 is a glutamate receptor and ion channel found in neurons. This receptor is thought to be very important for controlling synaptic plasticity and mediating learning and memory functions. Antibodies against NMDAR1 generate both neurologic and psychiatric symptoms. Common symptoms include personality change, psychosis, abnormal movements, seizures and autonomic dysfunction. Anti-NMDA receptor IgG antibody is found in a subset of patients with autoimmune limbic encephalitis and may occur with or without associated tumor. Decreasing antibody levels may be associated with therapeutic response; therefore, clinical correlation must be strongly considered. A negative test result does not rule…

Methodology

Immunofluorescence (IFA)

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

CSF or plasma; contaminated, hemolyzed, or severely lipemic specimens

Limitations

Results should not be used as a diagnostic procedure without confirmation by another medically established diagnostic product or procedure. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
505376NMDAR Antibody, Cell-based IFA93870-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86255

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation