Bismuth, Serum/Plasma: Quest Diagnostics test 8022
Quest Diagnostics test 8022, CPT 83018. Specimen: 1 mL serum collected in a no additive, trace metal-free (royal blue-top) tube.
Bismuth, Serum/Plasma is Quest Diagnostics test code 8022, billed with CPT 83018. Specimen: 1 mL serum collected in a no additive, trace metal-free (royal blue-top) tube. Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
Test code8022
CPT83018
LOINC—
Specimen1 mL serum collected in a no additive, trace metal-free (royal blue-top) tube
Minimum volume0.4 mL
ContainerAcid-washed or trace metal-free plastic screw-cap vial
Storage / transportRoom temperature
Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
Collection instructions
Promptly centrifuge and separate serum or plasma into an acid-washed or metal-free plastic screw-cap vial
Stability
| Temperature | Period |
|---|
| Room temperature | 30 days |
| Refrigerated | 30 days |
| Frozen | 30 days |
Causes for rejection
Polymer gel separation tube (SST or PST)
Notices
CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.
Assay category
This test was developed and its performance characteristics have been determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.
Alternative specimen(s)
Plasma collected in: EDTA trace metal-free (royal blue-top) tube or sodium heparin trace metal-free (royal blue-top) tube
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 83018
- Antimony, Blood
Quest DiagnosticsTest code 6035CPT 830181 mL blood collected in a Sarstedt S-Monovette® trace metal analysis; lithium he
- Antimony, Hair
Quest DiagnosticsTest code 6036CPT 83018500 mg hair
- Antimony, Serum/Plasma
Quest DiagnosticsTest code 6037CPT 830181 mL serum collected in a glass trace metal-free no additive (royal blue-top) tu
- Antimony, Urine
Quest DiagnosticsTest code 264CPT 82570, 830183 mL urine collected in a plastic urine container (acid-washed or trace metal-fr
- Barium Quantitative, Serum or Plasma
ARUP LaboratoriesTest code 0091282CPT 83018Royal blue (K2EDTA), royal blue (Na2EDTA), or royal blue (no additive).TAT 5-8 days
- Barium, Serum or Plasma
LabcorpTest code 811554CPT 83018Serum or plasmaTAT 5 - 9 days
- Barium, Serum/Plasma
Quest DiagnosticsTest code 5375CPT 830181 mL serum collected in a trace metal-free, no additive (royal blue-top) tube
- Barium, Urine
Quest DiagnosticsTest code 6054CPT 830181 mL urine collected in an acid-washed or trace metal-free plastic urine contain
- Barium, Urine
LabcorpTest code 811570CPT 83018Urine (random)TAT 5 - 9 days
- Barium, Whole Blood
LabcorpTest code 811562CPT 83018Whole bloodTAT 5 - 9 days
- Beryllium Quantitative, Serum or Plasma
ARUP LaboratoriesTest code 3000967CPT 83018Royal Blue (no additive) or Royal Blue (EDTA).TAT 8-11 days
- Beryllium, Blood
Quest DiagnosticsTest code 278CPT 830181 mL blood collected in a trace metal-free EDTA (royal blue-top) tube
- Beryllium, Serum or Plasma
LabcorpTest code 811745CPT 83018Serum or plasmaTAT 5 - 9 days
- Beryllium, Serum/Plasma
Quest DiagnosticsTest code 7131CPT 830182 mL serum collected in a no additive, trace metal-free (royal blue-top) tube
- Beryllium, Urine
LabcorpTest code 808540CPT 83018Urine (random)TAT 5 - 9 days
- Beryllium, Urine
Quest DiagnosticsTest code 6057CPT 82570, 830183 mL urine collected in a trace metal-free or acid-washed plastic urine containe
- Beryllium, Whole Blood
LabcorpTest code 811752CPT 83018Whole bloodTAT 3 - 7 days
- Bismuth, Blood
Quest DiagnosticsTest code 5374CPT 830184 mL whole blood collected in an EDTA trace metal-free (royal blue-top) tube
- Bismuth, Random Urine with Creatinine
Quest DiagnosticsTest code 6060CPT 82570, 830187 mL random urine collected in an acid-washed or metal-free container
- Bismuth, Whole Blood
ARUP LaboratoriesTest code 0099478CPT 83018Royal blue (K2EDTA) or royal blue (NaHep).TAT 1-3 days
- Boron Quantitative, Serum or Plasma
ARUP LaboratoriesTest code 0091330CPT 83018Royal blue (no additive), royal blue (K2EDTA), or royal blue (Na2EDTA).TAT 8-11 days
- Boron, Blood
Quest DiagnosticsTest code 3356CPT 830182 mL blood collected in an EDTA trace metal-free (royal blue-top) plastic tube
- Boron, Serum/Plasma
Quest DiagnosticsTest code 5301CPT 830182 mL serum collected in a trace metal-free no additive (royal blue-top) plastic
- Chromium and Cobalt, Whole Blood
LabcorpTest code 738770CPT 82495, 83018Whole bloodTAT 3 - 7 days
- Cobalt, Plasma
Cleveland Clinic LaboratoriesTest code COBALTCPT 83018PlasmaTAT 2 - 4 days
- Cobalt, Plasma
LabcorpTest code 071506CPT 83018PlasmaTAT 2 - 4 days
- Cobalt, Serum
Michigan Medicine Laboratories (MLabs)Test code COSCPT 830180.5 mL serumTAT 5 - 9 days
- Cobalt, Serum or Plasma
ARUP LaboratoriesTest code 0025037CPT 83018Royal blue (no additive), royal blue (K2EDTA), or royal blue (NaHep).TAT 1-3 days
- Cobalt, Urine
ARUP LaboratoriesTest code 0025032CPT 8301824-hour urine. Refrigerate during collection. Specimen must be collected in a plTAT 1-5 days
- Cobalt, Urine
LabcorpTest code 071514CPT 82570, 83018Urine (random or 24-hour)TAT 2 - 4 days
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.