Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Bismuth, Blood

Bismuth, Blood: Quest Diagnostics test 5374

Quest Diagnostics test 5374, CPT 83018. Specimen: 4 mL whole blood collected in an EDTA trace metal-free (royal blue-top) tube.

Bismuth, Blood is Quest Diagnostics test code 5374, billed with CPT 83018. Specimen: 4 mL whole blood collected in an EDTA trace metal-free (royal blue-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code5374
CPT83018
LOINC—
Specimen4 mL whole blood collected in an EDTA trace metal-free (royal blue-top) tube
Minimum volume2 mL
ContainerEDTA trace metal-free (royal blue-top) tube
Storage / transportRefrigerated (cold packs)

Methodology

Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

Stability

TemperaturePeriod
Room temperature48 hours
Refrigerated7 days
FrozenUnacceptable

Patient preparation

Avoid taking bismuth preparations such as Pepto-Bismol for at least 1 week prior to collection.

Causes for rejection

Gross hemolysis • Clotted

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes. This test code is for non-New York patient testing. For New York patient testing, see test code 13725.

Alternative specimen(s)

Whole blood collected in: Sodium heparin trace metal-free (royal blue-top) tube or sodium heparin lead-free (tan-top) tube Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level. If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that a re-submission with a trace element tube/container is recommended.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 83018

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation