Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Pre-biologic/biosimilar Screen Panel, HCV/HBV with Reflexes and QFT 4 Tubes

Pre-biologic/biosimilar Screen Panel, HCV/HBV with Reflexes and QFT 4 Tubes: Quest Diagnostics test 37620

Quest Diagnostics test 37620, CPT 86317, 86480, 86704, 86803, 87340. Specimen: 1 mL whole blood collected in each of the following tubes:.

Pre-biologic/biosimilar Screen Panel, HCV/HBV with Reflexes and QFT 4 Tubes is Quest Diagnostics test code 37620, billed with CPT 86317, 86480, 86704, 86803, 87340. Specimen: 1 mL whole blood collected in each of the following tubes:. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code37620
CPT86480, 87340, 86317, 86704, 86803
LOINC—
Specimen1 mL whole blood collected in each of the following tubes: QFT-Nil control (gray cap, white or gold ring) tube QFT-TB1 antigen (green cap, white or gold ring) tube QFT-TB2 antigen (yellow cap, white or gold ring) tube QFT-Mitogen control (purple cap, white or gold ring) tube and 2.5 mL serum collected in each of two separate serum separator tubes (SST) and 2.5 mL serum
Minimum volume0.8 mL whole blood in each tube • 2.5 mL serum in each of two separate serum separator tubes (SST) • 2.5 mL serum Collection instructions Note: Specimen collection locations >3350 feet above sea level should use the QuantiFERON® collection kit designed for "High Altitude" (tubes with a gold ring on tube top) For each patient, collect 1 mL of blood by venipuncture directly into each of the 4 QFT-PLUS blood collection tubes. These tubes should be at 17-25° C at the time of draw. If a "butterfly needle" is being used, a "purge" tube should be used to ensure that the tubing is filled with blood prior to the QFT-Plus tubes being used. Immediately after filling the tubes, shake them 10 times just firmly enough to ensure the entire surface of the tube is coated with blood, to solubilize antigens on tube walls. Each of the four tubes must be transferred to a 37° C plus or minus 1° C incubator as soon as possible and within 16 hours of collection for 16-24 hours. If the blood is not incubated immediately after collection, re-mixing of the tubes by inverting 10 times must be performed immediately prior to incubation. The specimen rack should sit off the floor of the incubator and the tubes should be upright. Following incubation either: A. Centrifuge each of the 4 incubated collection tubes for 15 minutes at 2000-3000 RCF(G). Label with patient name, identification number, and date of collection. Deliver to Quest Diagnostics at 2-8° C. Samples will be stable for 28 days at 2-8° C (refrigerated). *OR* B. Immediately transport the 4 collection tubes to Quest Diagnostics between 4 and 27° C. Samples will be stable for 72 hours at 4-27° C (refrigerated or at room temperature). The Centers for Disease Control and Prevention (CDC) has provided guidance on clinical considerations for tuberculosis (TB) testing such as QuantiFERON®-TB Gold Plus in conjunction with COVID-19 mRNA vaccines. Please refer to the QuantiFERON®-TB Gold Plus FAQ li

Also known as: Rituxan; Rituximab; Remicade; Infliximab; Tuberculosis; Humira; Immunosuppressed; Immunosuppressant; Immunocompromised; Hepatitis; Adalimumab; Enbrel; Enteracept

Methodology

See individual tests

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86317, 86480, 86704

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation