Diphtheria Antitoxoid Antibodies: Labcorp test 163709
Labcorp test 163709, CPT 86317. Specimen: Serum. Turnaround: 1 - 5 days.
Diphtheria Antitoxoid Antibodies is Labcorp test code 163709, billed with CPT 86317. Specimen: Serum. Turnaround time: 1 - 5 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Quest Diagnostics, Cleveland Clinic Laboratories.
Test code163709
CPT86317
LOINC5116-9
SpecimenSerum
Volume0.5 mL
Minimum volume0.25 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 5 days
Storage / transportRoom temperature
Also known as: Diphtheria Antibodies; Diphtheria Toxin Antibodies
Use
This test is used to assess immunity against diphtheria by determining levels of circulating antibodies to diphtheria toxin or to measure the immune response, postvaccination, in individuals suspected of immunodeficiency disorders.
Methodology
Enzyme immunoassay (EIA)
Stability
| Temperature | Period |
|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Gross hemolysis; lipemia; bacterial contamination
Reference range
• Nonprotective: <0.1 IU/mL
• Protective: ≥0.1 IU/mL
Limitations
This procedure is rarely used for confirmation of diphtheria infection; it cannot accurately discriminate antibodies between 0.10 IU/mL and 0.01 IU/mL. Immunity declines with age.
This procedure may be considered by Medicare and other carriers as investigational and, therefore, may not be payable as a covered benefit for patients.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 163710 | Diphtheria Antitoxoid Ab | IU/mL | 5116-9 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86317
- 14-3-3, Total Tau Protein and RT-QuIC, CSF
Michigan Medicine Laboratories (MLabs)Test code 1433CPT 0035U, 863172.0 mL CSFTAT 7 days for CSF testing, 3 days for a bio
- ABPA With Quantitative A. Fumigatus IgG
ARUP LaboratoriesTest code 3019329CPT 82785, 86003, 86317Plain red or serum separator tube.TAT 1-8 days
- Aspergillus Antibody Panel, CF and ID, Serum
Quest DiagnosticsTest code 91846CPT 86317, 866061 mL serum
- Aspergillus fumigatus Antibody IgG
Cleveland Clinic LaboratoriesTest code ASPIGGCPT 86317SerumTAT 2 - 9 days
- Aspergillus fumigatus Antibody IgG
ARUP LaboratoriesTest code 3000876CPT 86317Plain red or serum separator tube (SST)TAT 1-8 days
- Coxsackie A Antibodies (Serotypes 2, 4, 7, 9, 10, and 16), Serum
ARUP LaboratoriesTest code 2002932CPT 86317Plain red or serum separator tube (SST).TAT 6-11 days
- Coxsackie A, 6 Antibodies
Cleveland Clinic LaboratoriesTest code COXSA6CPT 86317SerumTAT 7 - 12 days
- Creutzfeldt-Jakob Disease
Cleveland Clinic LaboratoriesTest code CJDCPT 0035U, 84182, 86317Cerebrospinal fluid (CSF)TAT 8 - 11 days
- Diphtheria & Tetanus Antibodies, IgG
ARUP LaboratoriesTest code 0050595CPT 86317Serum separator tube. "Pre" and "post" vaccination specimens should be submittedTAT 1-3 days
- Diphtheria Antibody, IgG
ARUP LaboratoriesTest code 0050210CPT 86317Serum separator tube. "Pre" and "post" vaccination specimens should be submittedTAT 1-3 days
- Diphtheria Toxoid IgG Abs
Cleveland Clinic LaboratoriesTest code DIPIGGCPT 86317SerumTAT 2 - 4 days
- Diphtheria Toxoid IgG Antibody
Michigan Medicine Laboratories (MLabs)Test code DIPGSCPT 863170.5 mL serumTAT 2 - 5 days
- Diphtheria, Tetanus, and H. Influenzae b Antibodies, IgG
ARUP LaboratoriesTest code 0050779CPT 86317Serum separator tube or red tube.TAT 1-3 days
- Diphtheria/Tetanus Antibody
Cleveland Clinic LaboratoriesTest code DIPTETCPT 86317SerumTAT 2 - 4 days
- Fungal Antibodies Panel
Cleveland Clinic LaboratoriesTest code FUNPANCPT 86317, 86612, 86635, 86698SerumTAT Refer to individual components
- Haemophilus influenzae B Ab IgG
Cleveland Clinic LaboratoriesTest code HINFLUCPT 86317SerumTAT 2 - 4 days
- Haemophilus influenzae b Antibody, IgG
ARUP LaboratoriesTest code 0050542CPT 86317Serum separator tube. "Pre" and 30-day "post" Haemophilus influenzae b vaccinatiTAT 1-3 days
- Haemophilus influenzae B, IgG
LabcorpTest code 138271CPT 86317SerumTAT 2 - 4 days
- Hepatitis B Surface Antibody, Quantitative
LabcorpTest code 006530CPT 86317SerumTAT 1 - 2 days
- Humoral Immunity Panel I
ARUP LaboratoriesTest code 0050980CPT 82784, 82787, 86317, 86581Serum separator tube.TAT 1-4 days
- Humoral Immunity Panel II
ARUP LaboratoriesTest code 0050981CPT 86317, 86581Serum separator tube.TAT 1-4 days
- Pneumococcal IgG Antibodies, 23 Serotypes
Cleveland Clinic LaboratoriesTest code PNE23CPT 86317SerumTAT 2 - 6 days
- Pre-Biologic Screening Profile
LabcorpTest code 144441CPT 86317, 86480, 86704, 86803, 87340Serum and whole bloodTAT 3 - 5 days
- Prion Markers (CJD) in CSF
ARUP LaboratoriesTest code 3019310CPT 0035U, 86317Cerebrospinal fluid (CSF)TAT 8-11 days
- Tetanus Antibody, IgG
ARUP LaboratoriesTest code 0050535CPT 86317Serum separator tube. "Post" specimen should be drawn 30 days after immunizationTAT 1-3 days
- Tetanus Antitoxoid Antibodies
LabcorpTest code 163691CPT 86317SerumTAT 1 - 5 days
- Tetanus Toxoid IgG
Cleveland Clinic LaboratoriesTest code TETANCPT 86317SerumTAT 2 - 4 days
- Tetanus Toxoid IgG Antibody
Michigan Medicine Laboratories (MLabs)Test code TTIGSCPT 863170.5 mL serumTAT 1 - 4 days
- Tetanus/Diphtheria Antibody Profile
LabcorpTest code 163253CPT 86317SerumTAT 1 - 6 days
- Pre-Biologic Screening Profile
LabcorpTest code 144441Women's HealthCPT 86317, 86480, 86704, 86803, 87340Serum and whole bloodTAT 3 - 5 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation