Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Sexually-Transmitted Infections (STIs) Increased Risk Panel

Sexually-Transmitted Infections (STIs) Increased Risk Panel: Quest Diagnostics test 36963

Quest Diagnostics test 36963, CPT 87494, 87563, 87661. Specimen: Female.

Sexually-Transmitted Infections (STIs) Increased Risk Panel is Quest Diagnostics test code 36963, billed with CPT 87494, 87563, 87661. Specimen: Female. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Allina Health Laboratory (Abbott Northwestern), ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code36963
CPT87494, 87661, 87563 CPT coding may differ dependent on payer rules which may impact prior authorization testing. Please direct any questions regarding CPT coding to the payer being billed.
LOINC—
SpecimenFemale Vaginal or endocervical swab collected in an Aptima® transport tube or 2 mL urine collected in an Aptima transport tube Male Urethral swab collected in an Aptima transport tube or 2 mL urine collected in an Aptima transport tube
ContainerSee Collection Instructions
Storage / transportRoom temperature

Also known as: Trichomoniasis; Vaginitis; CT/GC APTIMA®; Urine Trichomonas; CT/NG APTIMA®; CT/NG TMA; STI Increased Risk Panel; STD Panel; Mycoplasma genitalium TMA; Hologic

Methodology

Transcription-Mediated Amplification (TMA)

Collection instructions

Vaginal swab: Follow instructions in the Aptima Multitest Swab Specimen Collection Kit (orange label). Age restrictions may apply. See individual tests for further information. Endocervical or urethral swabs: Follow instructions in the Aptima Unisex Swab Specimen Collection Kit (white label). In females, to ensure collection of cells infected with N. gonorrhoeae/C. trachomatis, columnar epithelial cells lining the endocervix should be obtained. Excess mucus should be removed prior to sampling. Urine: Direct patient to provide first-catch urine (a maximum of 20-30 mL of the initial urine stream) into a urine collection cup free of any preservatives. 2 mL of urine specimen must be transferred into the Aptima specimen transport within 24 hours of collection and before being assayed. Use tube provided in the urine specimen collection kit. The fluid (urine plus transport media) level in the urine tube must fall within the clear pane on the tube label.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen30 days

Patient preparation

Urine: Patient should not have urinated within one hour prior to collection. Female patients should not cleanse the labial area prior to providing the specimen.

Causes for rejection

Transport tubes with 2 swabs • Transport tubes with Non-Aptima swab • Swab transport tubes with no swab • Swab or urine submitted in Non-Aptima transport tube • Urine samples where the fluid level is not between the black fill lines • Raw urine • ThinPrep® vial

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87494, 87563, 87661

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation