Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Chlamydia trachomatis and Neisseria gonorrhoeae by Transcription-Mediated Amplification (TMA), ThinPrep

Chlamydia trachomatis and Neisseria gonorrhoeae by Transcription-Mediated Amplification (TMA), ThinPrep: ARUP Laboratories test 0060734

ARUP Laboratories test 0060734, CPT 87494. Specimen: Cervical specimen with the ThinPrep Pap Test Collection Kit. Refer to "Sample Collection for the Diagnosis of STD" under. Turnaround: 1-4 days.

Chlamydia trachomatis and Neisseria gonorrhoeae by Transcription-Mediated Amplification (TMA), ThinPrep is ARUP Laboratories test code 0060734, billed with CPT 87494. Specimen: Cervical specimen with the ThinPrep Pap Test Collection Kit. Refer to "Sample Collection for the Diagnosis of STD" under Specimen Handling a. Turnaround time: 1-4 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0060734
CPT87494
LOINC31208-2, 43304-5, 43305-2
SpecimenCervical specimen with the ThinPrep Pap Test Collection Kit. Refer to "Sample Collection for the Diagnosis of STD" under Specimen Handling at www.aruplab.com for specific specimen collection and transport instructions.
Turnaround time1-4 days
Storage / transportRefrigerated.

Also known as: Chlamydia and GC TMA panel; CT/GC TMA ThinPrep; Gonorrhea ThinPrep; Nucleic Acid Amplification Test

Use

Can be used to detect Chlamydia trachomatis and Neisseria gonorrhoeae in ThinPrep specimens. This test does not include confirmation of positive results by an alternative nucleic acid target. If confirmation of positive results by an alternate nucleic acid target is required, refer to Chlamydia trachomatis and Neisseria gonorrhoeae (CTNG) by Transcription-Mediated Amplification (TMA) with Reflex to CT/NG Confirmation ( 2011164 ).

Methodology

Transcription-Mediated Amplification (TMA)

Collection instructions

Vortex ThinPrep PreservCyt solution and transfer 1 mL to an APTIMA Specimen Transfer Tube (ARUP supply # 42711 ). Available online through eSupply using ARUP Connect (TM) or contact ARUP Client Services at (800) 522-2787. To reduce the potential for contamination, ThinPrep specimens should be poured off, using sterile technique, into the APTIMA Specimen Transfer Tube prior to Cytology Testing.

Stability

ThinPrep PreservCyt solution: Ambient: 1 month; Refrigerated: 1 month; Frozen: Unacceptable APTIMA Specimen Transfer Tube: Ambient: 2 weeks; Refrigerated: 1 month; Frozen: 12 months

Causes for rejection

Specimens in any transport media other than indicated above. Specimens from patients that are less than 14 years of age.

Reference range

Test Number Components Reference Interval C. trachomatis by TMA, ThinPrep Negative N. gonorrhoeae by TMA, ThinPrep Negative

Remarks

Specimen source is required.

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0060733C. trachomatis by TMA, ThinPrep43304-5
0060735N. gonorrhoeae by TMA, ThinPrep43305-2
2005507Specimen Source31208-2

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 87494

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation