Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Infliximab Level

Infliximab Level: Quest Diagnostics test 36303

Quest Diagnostics test 36303, CPT 80230. Specimen: 0.5 mL serum.

Infliximab Level is Quest Diagnostics test code 36303, billed with CPT 80230. Specimen: 0.5 mL serum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code36303
CPT80230
LOINC—
Specimen0.5 mL serum
Minimum volume0.3 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)

Also known as: TNF inhibitor; Remsima™; Renflexis™; Remicade®; Inflectra™; infliximab-dyyb; Anti-TNF; TNF blocker

Methodology

Chemiluminescent Immunoassay

Stability

TemperaturePeriod
Room temperature48 hours
Refrigerated7 days
Frozen -20° C28 days
Frozen -70° C6 months

Patient preparation

Collect immediately before next scheduled dose (trough specimen)

Causes for rejection

Moderate and gross hemolysis

Reference range

See Laboratory Report

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 80230

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation