Sound Lab Consultants › National Lab Test Directory › Labcorp › Infliximab and Anti-Infliximab Antibody, DoseASSURE™ IFX

Infliximab and Anti-Infliximab Antibody, DoseASSURE™ IFX: Labcorp test 503870

Labcorp test 503870, CPT 80230, 82397. Specimen: Serum (preferred) or plasma. Turnaround: 5 - 10 days.

Infliximab and Anti-Infliximab Antibody, DoseASSURE™ IFX is Labcorp test code 503870, billed with CPT 80230, 82397. Specimen: Serum (preferred) or plasma. Turnaround time: 5 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code503870
CPT80230; 82397
LOINC39803-2, 72623-2
SpecimenSerum (preferred) or plasma
Volume2 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing).
ContainerRed-top tube, gel-barrier tube or plasma from green-top tube
Turnaround time5 - 10 days
Storage / transportFrozen (preferred) or refrigerated

Also known as: Anti-TNF-alpha Drug; DoseASSURE; IFD; Remicade

Test includes

This test includes serial monitoring.

Use

Provides infliximab drug concentration levels as well as levels of anti-infliximab antibodies. In the absence of anti-infliximab antibodies, the infliximab drug level typically reflects the total infliximab concentration in serum. In the presence of anti-infliximab antibodies, the infliximab drug level typically reflects the antibody-unbound fraction of infliximab concentration in serum. The presence of infliximab drug, even at concentrations well above target treatment levels (>50 ug/mL), does not interfere with the anti-infliximab antibody detection. This assay may be helpful for any patients on infliximab therapy for diseases such as Crohn's disease, inflammatory bowel disease,…

Methodology

Electrochemiluminescence Immunoassay (ECLIA)

Collection instructions

Send serum in a plastic transport tube. To avoid delays in turnaround time when requesting multiple test on frozen samples, please submit separate frozen specimens for each test requested.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
Frozen359 days
Freeze/thaw cyclesStable x6

Limitations

Failure of infliximab therapy may not always be due to the presence of anti-infliximab antibodies. In addition, the absence of anti-infliximab antibodies does not guarantee positive response to treatment. High serum biotin concentrations in patients taking biotin supplements may cause an interference in this assay. Patients may be advised to stop biotin consumption at least 72 hours prior to sample collection.

LOINC map

Result codeResult nameUnitsResult LOINC
503772Infliximab Drug Levelug/mL39803-2
503773Anti-Infliximab Antibodyng/mL72623-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 80230, 82397

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation