Cholinesterase, RBC and Plasma: Quest Diagnostics test 338

Quest Diagnostics test 338, CPT 82480, 82482. Specimen: 4 mL whole blood collected in an EDTA (lavender-top) and.

Cholinesterase, RBC and Plasma is Quest Diagnostics test code 338, billed with CPT 82480, 82482. Specimen: 4 mL whole blood collected in an EDTA (lavender-top) and. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code338
CPT82480, 82482
LOINC—
Specimen4 mL whole blood collected in an EDTA (lavender-top) and 1 mL plasma collected in an EDTA (lavender-top)
Minimum volume3 mL whole blood • 0.5 mL plasma
ContainerEDTA (lavender-top) tube and transport tube
Storage / transportRefrigerated (cold packs)

Also known as: RBC Cholinesterase

Methodology

Kinetic Spectrophotometric (KS)

Collection instructions

Draw two EDTA (lavender-top) tubes of whole blood. Spin one tube to separate plasma. Pour plasma into plastic aliquot tube (label this vial as plasma). Send one 4 mL refrigerated uncentrifuged whole blood (3 mL minimum) and 1 mL refrigerated plasma (0.5 mL minimum). Do not send packed cells. Do not send only one tube of whole blood. Plasma cholinesterase results, as well as the calculated RBC cholinesterase results, are not accurate if plasma sample is not separated from the RBC's in a timely manner. Hemolyzed plasma samples are not acceptable. Hemolysis can lead to apparent increases in plasma cholinesterase activity, and could mask an enzyme deficiency.

Stability

TemperaturePeriod
Room temperature24 hours
Refrigerated7 days
FrozenUnacceptable

Causes for rejection

Hemolysis • Lipemia • Received room temperature • Receipt of only a single tube of whole blood

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes. This test code is for non-California patient testing. For California patient testing, use test code 90372.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82480, 82482

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation