Pseudocholinesterase, Dibucaine Inhibition: ARUP Laboratories test 0020159
ARUP Laboratories test 0020159, CPT 82480, 82638. Specimen: Serum separator tube, plain red, green (sodium or lithium heparin), lavender (EDTA), or pink (K2EDTA).. Turnaround: 1-5 days.
Also known as: Butyrylcholinesterase; Cholinesterase; Cholinesterase, Serum; Dibucaine; Dibucaine Inhibition; Dibucaine Number; Serum Cholinesterase; Serum Pseudocholinesterase
Use
Order to detect increased sensitivity in individuals who experience prolonged paralysis following succinylcholine or mivacurium administration.
Methodology
Quantitative Enzymatic Assay
Collection instructions
Allow specimen to clot completely at room temperature. Separate serum or plasma from cells ASAP or within 2 hours of collection. Transport 1 mL serum or plasma. (Min: 0.25 mL)
Stability
Room Temperature: 4 hours; Refrigerated: 1 week; Frozen: 3 months
Patient preparation
Specimen must be drawn prior to surgery or more than two days following surgery. Do not draw in recovery room.
Causes for rejection
Lt. blue (sodium citrate) or gray (oxalate/fluoride). Whole blood.
Reference range
Test Number Components Reference Interval Pseudocholinesterase, Total 2,900-7,100 U/L Dibucaine Number Greater than or equal to 80
Performed
Mon-Fri
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 0020059 | Pseudocholinesterase, Total | 2098-2 | |
| 0020060 | Dibucaine Number | 39354-6 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 82480, 82638
- Cholinesterase
- Insecticide Exposure Panel
- Pseudocholinesterase
- Pseudocholinesterase Phenotype
- Pseudocholinesterase, Total
- Pseudocholinesterase, Total
- Dibucaine Number
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations