Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Amikacin, Peak and Trough

Amikacin, Peak and Trough: Quest Diagnostics test 250

Quest Diagnostics test 250, CPT 80150. Specimen: 1 mL serum collected in each of two separate red-top tubes (no gel).

Amikacin, Peak and Trough is Quest Diagnostics test code 250, billed with CPT 80150. Specimen: 1 mL serum collected in each of two separate red-top tubes (no gel). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code250
CPT80150 (x2)
LOINC—
Specimen1 mL serum collected in each of two separate red-top tubes (no gel)
Minimum volume0.2 mL for each specimen
ContainerTransport tube(s)
Storage / transportRoom temperature

Also known as: Amikin

Methodology

Immunoassay (IA)

Collection instructions

Clearly mark each specimen peak or trough

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
Frozen7 days

Patient preparation

Collect peak at end of a 60 minute IV infusion, or 30 minutes after end of 30 minute infusion, or 60 minutes after IM dose. Collect as a trough just prior to next dose.

Causes for rejection

Serum separator tube (SST) • Heparin plasma

Notices

Not offered in Quest Diagnostics Nichols Institute (IFD) – San Juan Capistrano. Please provide Service area information to confirm Test Code for the lab that services your account or to find available tests you can order.

Alternative specimen(s)

Plasma collected in: Fluoride oxalate (gray-top) tube or EDTA (lavender-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 80150

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation