Amikacin, Peak and Trough: Quest Diagnostics test 250
Quest Diagnostics test 250, CPT 80150. Specimen: 1 mL serum collected in each of two separate red-top tubes (no gel).
Amikacin, Peak and Trough is Quest Diagnostics test code 250, billed with CPT 80150. Specimen: 1 mL serum collected in each of two separate red-top tubes (no gel). Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
Test code250
CPT80150 (x2)
LOINC—
Specimen1 mL serum collected in each of two separate red-top tubes (no gel)
Minimum volume0.2 mL for each specimen
ContainerTransport tube(s)
Storage / transportRoom temperature
Also known as: Amikin
Methodology
Immunoassay (IA)
Collection instructions
Clearly mark each specimen peak or trough
Stability
| Temperature | Period |
|---|
| Room temperature | 7 days |
| Refrigerated | 7 days |
| Frozen | 7 days |
Patient preparation
Collect peak at end of a 60 minute IV infusion, or 30 minutes after end of 30 minute infusion, or 60 minutes after IM dose. Collect as a trough just prior to next dose.
Causes for rejection
Serum separator tube (SST) • Heparin plasma
Notices
Not offered in Quest Diagnostics Nichols Institute (IFD) – San Juan Capistrano. Please provide Service area information to confirm Test Code for the lab that services your account or to find available tests you can order.
Alternative specimen(s)
Plasma collected in: Fluoride oxalate (gray-top) tube or EDTA (lavender-top) tube
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 80150
- Amikacin
Michigan Medicine Laboratories (MLabs)Test code AMKR (random), AMKTR (trough), AMKPK (peak)CPT 801500.5 mL serumTAT 2 hours
- Amikacin
Quest DiagnosticsTest code 236CPT 801501 mL serum collected in a red-top tube (no gel)
- Amikacin Level, Peak, Serum
ARUP LaboratoriesTest code 3018769CPT 80150Serum separator tube (SST). Also acceptable: Plain red.TAT 3-4 days
- Amikacin Level, Random, Serum
ARUP LaboratoriesTest code 3018754CPT 80150Serum separator tube (SST). Also acceptable: Plain redTAT 3-6 days
- Amikacin Level, Trough, Serum
ARUP LaboratoriesTest code 3018756CPT 80150Serum separator tube (SST). Also acceptable: Plain redTAT 3-6 days
- Amikacin, Peak
LabcorpTest code 007204CPT 80150Serum or plasmaTAT 1 - 3 days
- Amikacin, Peak
Quest DiagnosticsTest code 8584CPT 801501 mL serum collected in a red-top tube (no gel)
- Amikacin, Post Dose
Cleveland Clinic LaboratoriesTest code AMIKPOCPT 80150PlasmaTAT 8 hours
- Amikacin, Pre Dose
Cleveland Clinic LaboratoriesTest code AMIKPRCPT 80150PlasmaTAT 8 hours
- Amikacin, Random
Cleveland Clinic LaboratoriesTest code AMIKRACPT 80150PlasmaTAT 8 hours
- Amikacin, Trough
LabcorpTest code 007205CPT 80150Serum or plasmaTAT 1 - 3 days
- Amikacin, Trough
Quest DiagnosticsTest code 8583CPT 801501 mL serum collected in a red-top tube (no gel)
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation