Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Amikacin, Peak

Amikacin, Peak: Labcorp test 007204

Labcorp test 007204, CPT 80150. Specimen: Serum or plasma. Turnaround: 1 - 3 days.

Amikacin, Peak is Labcorp test code 007204, billed with CPT 80150. Specimen: Serum or plasma. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code007204
CPT80150
LOINC3319-1
SpecimenSerum or plasma
Volume1 mL
Minimum volume0.3 mL
ContainerRed-top tube or green-top (heparin) tube. Do not use a gel-barrier tube. The use of gel-barrier tubes is not recommended due to slow absorption of the drug by the gel. Depending on the specimen volume and storage time, the decrease in drug level due to absorption may be clinically significant.
Turnaround time1 - 3 days
Storage / transportRoom temperature

Also known as: Amikin®

Use

Amikacin is used to treat serious infections caused by susceptible aerobic gram-negative bacilli (eg, a number of the Enterobacteriaceae, P aeruginosa ). Such infections include bacteremias; intra-abdominal, soft tissue (including burns), bone or joint, lower respiratory tract, and complicated urinary tract infections, and meningitis. The major advantage of amikacin is its superior resistance profile. Thus, it is the aminoglycoside of choice for infections caused by aerobic gram-negative bacilli that are known or suspected to be resistant to other aminoglycosides. It should be the aminoglycoside of choice for general use in hospitals where the prevalence of resistance to gentamicin and…

Methodology

Immunoassay (IA)

Collection instructions

Transfer separated serum or plasma to a plastic transport tube. Both peak and trough concentrations should be monitored. The trough sample is drawn immediately prior to the next dose. Peak samples should be drawn 60 minutes after an IM injection, 30 minutes after the end of a 30-minute IV infusion, or immediately after a 60-minute IV infusion.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gel-barrier tube; severe hemolysis; lipemia; icteric specimen

Reference range

Therapeutic : peak: 20.0−30.0 μg/mL, trough: 1.0−8.0 μg/mL

Special instructions

Peak levels should be ordered using Test No. 007204. Trough levels should be ordered using Test No. 007205. Please label tubes appropriately as "peak" and "trough."

LOINC map

Result codeResult nameUnitsResult LOINC
007204Amikacin Peak, Serumug/mL3319-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 80150

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation