Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Androstenedione, Response to ACTH Stimulation

Androstenedione, Response to ACTH Stimulation: Quest Diagnostics test 19511

Quest Diagnostics test 19511, CPT 82157. Specimen: 1 mL serum per specimen collected in a red-top tube (no gel).

Androstenedione, Response to ACTH Stimulation is Quest Diagnostics test code 19511, billed with CPT 82157. Specimen: 1 mL serum per specimen collected in a red-top tube (no gel). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code19511
CPT82157 (x2)
LOINC—
Specimen1 mL serum per specimen collected in a red-top tube (no gel)
Minimum volume0.25 mL each specimen
ContainerTransport tube(s)
Storage / transportRefrigerated (cold packs)

Also known as: Androstenedione; Baseline; Androstenedione; 60 Minutes

Methodology

Chromatography/Mass Spectrometry

Collection instructions

Serum separator tubes are unacceptable. Draw blood in a red-top tube (no gel). Separate serum after clotting. Do not submit glass tubes. An early morning specimen is preferred. Draw baseline specimen. Draw another specimen 60 minutes after stimulation. Note: Cortrosyn (cosyntropin) not supplied by the laboratory. This test cannot be collected at a Patient Service Center.

Stability

TemperaturePeriod
Room temperature72 hours
Refrigerated28 days
Frozen2 years

Causes for rejection

Gross hemolysis • Samples collected in serum separator tubes (SST)

Reference range

See Laboratory Report

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Plasma collected in: EDTA (lavender-top), EDTA (royal blue-top), sodium heparin (green-top), or lithium heparin (green-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82157

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation