Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Androstenedione by Ionify LC-MS/MS

Androstenedione by Ionify LC-MS/MS: Labcorp test 004774

Labcorp test 004774, CPT 82157. Specimen: Serum (preferred) or plasma. Turnaround: 3 - 5 days.

Androstenedione by Ionify LC-MS/MS is Labcorp test code 004774, billed with CPT 82157. Specimen: Serum (preferred) or plasma. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004774
CPT82157
LOINC107493-9
SpecimenSerum (preferred) or plasma
Volume1.5 mL
Minimum volume0.7 mL
ContainerRed-top tube (preferred); plasma from green-top (lithium heparin) or plasma from lavender-top (EDTA) tube are also acceptable
Turnaround time3 - 5 days
Storage / transportRefrigerate.

Also known as: 4-Adrostenedione; delta-4-Androstene; 3,17-dione

Use

The determination of androstenedione is used as an aid in diagnosis and differential diagnosis of androgens related endocrine function in conjunction with other clinical and laboratory findings.

Methodology

Ionify LC-MS/MS

Collection instructions

Transfer serum or plasma to a plastic transfer tube. Do not use a gel-barrier tube. The use of gel-barrier tubes is not recommended due to slow absorption of the steroid by the gel. Depending on the specimen volume and storage time, the decrease in androstenedione level due to absorption may be clinically significant.

Stability

TemperaturePeriod
Room temperature5 days (stability provided by manufacturer or literature reference)
Refrigerated14 days (stability provided by manufacturer or literature reference)
Frozen12 weeks (stability provided by manufacturer or literature reference)
Freeze/thaw cyclesStable x1 (stability provided by manufacturer or literature reference)

Causes for rejection

Gel-barrier tube received, unspun sample

Reference range

See table. Age Male (ng/dL) Female (ng/dL) 0 to 6 m 7 m to 2 y 2 to 6 y 6 to 8 y 9 to 14 y 15 to 60 y 61 to 80 y >80 y

LOINC map

Result codeResult nameUnitsResult LOINC
004395Androstenedione, LC-MS/MSng/dL107493-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82157

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation