Donor, HTLV-I/II Antibody Screen: Quest Diagnostics test 17379
Quest Diagnostics test 17379, CPT 86790. Specimen: 2 mL serum or plasma collected in an EDTA (lavender-top) tube.
Donor, HTLV-I/II Antibody Screen is Quest Diagnostics test code 17379, billed with CPT 86790. Specimen: 2 mL serum or plasma collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
Test code17379
CPT86790
LOINC—
Specimen2 mL serum or plasma collected in an EDTA (lavender-top) tube
Minimum volume1 mL
ContainerTransport tube
Storage / transportRoom temperature
Also known as: Donor; HTL-V/II Antibody; HTLVI; Donor; HTL-V/II; Donor; HTLV-VI; Donor; DONOR TESTING ONLY
Methodology
Immunoassay (IA)
Collection instructions
Label the tubes according to your standard operating procedure, making sure that each tube has at least two unique patient identifiers.
If transport temperature will be frozen, centrifuge the red/lavender top tube and transfer the serum/plasma into a plastic screw-cap vial. The plastic screw-cap vial (aliquot tube) containing serum or plasma must be labeled with the specimen type (serum or plasma) and at least two unique patient identifiers. Aliquot tubes must be processed and labeled at the original collection site. If aliquot tubes are submitted, do not send the original red/lavender top tube.
Please note: This test is to be used for the screening of DONORS of human cells, tissues, and cellular and tissue-based products for infectious disease.
For Shipper collection please see detailed instructions in Test Resources.
Stability
| Temperature | Period |
|---|
| Room temperature | 7 days |
| Refrigerated | 14 days |
| Frozen | 90 days |
Causes for rejection
Gross hemolysis • Sample not marked serum/plasma • Specimens other than serum or plasma • Heat-inactivated specimens • Pooled specimens • Specimens with obvious microbial contamination • Specimens with fungal growth
Reference range
Non-Reactive
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 86790
- Chikungunya Antibodies (IgG, IgM) with Reflex to Titers
Quest DiagnosticsTest code 70188CPT 867900.5 mL serum
- Chikungunya Antibodies, IgG and IgM
ARUP LaboratoriesTest code 2011812CPT 86790Serum separator tube (SST). Also acceptable: Plain red or plasma (heparin, citraTAT 1-8 days
- Chikungunya Antibodies, IgG and IgM
Cleveland Clinic LaboratoriesTest code CHIKGMCPT 86790SerumTAT 2 - 9 days
- Chikungunya Antibody, IgG
ARUP LaboratoriesTest code 2011808CPT 86790Serum separator tube (SST). Also acceptable: Plain red or plasma (heparin, citraTAT 1-8 days
- Chikungunya Antibody, IgM
ARUP LaboratoriesTest code 2011810CPT 86790Serum separator tube (SST). Also acceptable: Plain red or plasma (heparin, citraTAT 1-8 days
- Colorado Tick Fever Antibody Panel, IFA
Quest DiagnosticsTest code 34986CPT 867901 mL serum
- Dengue Fever Abs IgG & IgM
Cleveland Clinic LaboratoriesTest code DENGTCPT 86790SerumTAT 2 - 10 days
- Dengue Fever Antibodies (IgG, IgM)
Quest DiagnosticsTest code 93256CPT 867901 mL serum
- Dengue Fever Antibodies (IgG, IgM) and NS1 Antigen Panel
Quest DiagnosticsTest code 93192CPT 86790, 874491.5 mL serum
- Dengue Fever Antibody (IgG)
Quest DiagnosticsTest code 37579CPT 867900.5 mL serum
- Dengue Fever Antibody (IgM)
Quest DiagnosticsTest code 37580CPT 867901 mL serum
- Dengue Fever Antibody, IgG & IgM
Michigan Medicine Laboratories (MLabs)Test code FDFACPT 867900.5 mL serumTAT 1 - 4 days
- Dengue Fever Virus Antibodies, IgG and IgM
ARUP LaboratoriesTest code 0093096CPT 86790Serum separator tube.TAT 1-5 days
- Dengue Fever Virus Antibody, IgG
ARUP LaboratoriesTest code 0093097CPT 86790Serum separator tube.TAT 1-5 days
- Dengue Fever Virus Antibody, IgM
ARUP LaboratoriesTest code 0093098CPT 86790Serum separator tube.TAT 1-5 days
- Dengue Virus IgG Antibody
Cleveland Clinic LaboratoriesTest code DENIGGCPT 86790SerumTAT 2 - 6 days
- Dengue Virus IgM Abs
Cleveland Clinic LaboratoriesTest code DENIGMCPT 86790SerumTAT 2 - 10 days
- Donor, Stem Cells Donor Panel
Quest DiagnosticsTest code 93309CPT 86644, 86703, 86704, 86780, 86790, 86803, 87340, 87798, 878016 mL serum collected in each of two separate tubes and
- Hantavirus IgG & IgM Abs
Cleveland Clinic LaboratoriesTest code HANTABCPT 86790SerumTAT 2 - 4 days
- Hepatitis E Antibody IgG
Cleveland Clinic LaboratoriesTest code HEPIGGCPT 86790SerumTAT 2 - 6 days
- Hepatitis E Antibody IgM
Cleveland Clinic LaboratoriesTest code HEPIGMCPT 86790SerumTAT 2 - 6 days
- Hepatitis E Antibody, IgG
Michigan Medicine Laboratories (MLabs)Test code HEPEGCPT 867900.5 mL serumTAT 5 - 9 days
- Hepatitis E Antibody, IgM
Michigan Medicine Laboratories (MLabs)Test code HEPEMCPT 867900.5 mL serumTAT 5 - 9 days
- Hepatitis E Virus (HEV) Antibodies, IgG and IgM
ARUP LaboratoriesTest code 2012023CPT 86790Serum separator tube (SST). Also acceptable: lavender (K2EDTA), lavender (K3EDTATAT 1-5 days
- Hepatitis E Virus (HEV) Antibodies, IgG and IgM
Cleveland Clinic LaboratoriesTest code HEPECPT 86790SerumTAT 2 - 6 days
- Hepatitis E Virus (HEV) Antibody, IgG
ARUP LaboratoriesTest code 2010151CPT 86790Serum separator tube. Also acceptable: Red (clot activator), lavender (EDTA), piTAT 1-5 days
- Hepatitis E Virus (HEV) Antibody, IgM
ARUP LaboratoriesTest code 2010156CPT 86790Serum separator tube. Also acceptable: Red (clot activator), lavender (EDTA), piTAT 1-5 days
- Herpesvirus 6 Antibody, IgG
ARUP LaboratoriesTest code 2013423CPT 86790Plain red or serum separator tube (SST).TAT 5-9 days
- Herpesvirus 6 Antibody, IgM by IFA, Serum
ARUP LaboratoriesTest code 3001284CPT 86790Plain red or serum separator tube (SST).TAT 5-9 days
- Herpesvirus 6 Human IgG & IgM Abs
Cleveland Clinic LaboratoriesTest code HV6ABSCPT 86790SerumTAT 2 - 4 days
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation