Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Bacterial 16S rDNA Sequencing

Bacterial 16S rDNA Sequencing: Quest Diagnostics test 17221

Quest Diagnostics test 17221, CPT 87153.

Bacterial 16S rDNA Sequencing is Quest Diagnostics test code 17221, billed with CPT 87153. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code17221
CPT87153
LOINC—
ContainerDouble-walled safety container
Storage / transportRoom temperature

Methodology

16S Sequencing

Collection instructions

Subculture isolate to the appropriate agar slant. Submit in double-walled safety container.

Stability

TemperaturePeriod
Room temperatureDetermined by viability
RefrigeratedDetermined by viability
FrozenUnacceptable

Patient preparation

None Specified Preferred specimen(s) Culture isolate in agar slant double-walled container

Causes for rejection

Mixed culture • Received frozen

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87153

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation