Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Organism Identification, Unspecified Group, by Sequence Analysis

Organism Identification, Unspecified Group, by Sequence Analysis: Labcorp test 183285

Labcorp test 183285, CPT 87153. Specimen: Pure culture isolate of bacteria, yeast, mold, Nocardia , or mycobacteria. Turnaround: 14 - 30 days.

Organism Identification, Unspecified Group, by Sequence Analysis is Labcorp test code 183285, billed with CPT 87153. Specimen: Pure culture isolate of bacteria, yeast, mold, Nocardia , or mycobacteria. Turnaround time: 14 - 30 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code183285
CPT87153
LOINC—
SpecimenPure culture isolate of bacteria, yeast, mold, Nocardia , or mycobacteria
VolumePure culture isolate (visible colonies should be present).
Minimum volumeViable colonies macroscopically visible.
ContainerBacterial swab transport inoculated with the isolate from a pure culture or agar slant in screw-cap container packed as an etiologic agent. Maintain a subculture at the submitting laboratory.
Turnaround time14 - 30 days
Storage / transportMaintain media at room temperature. Ensure that plated media has been securely sealed with parafilm.

Use

If MALDI-TOF based identification has not been performed, test code 183402 should be ordered. Determine the identification of isolates (ie, bacterial, fungal, mycobacterial, etc) from another laboratory that has performed culture of the clinical specimen. These isolates may include strict aerobes, facultative anaerobes, anaerobes, yeast, filamentous fungi, mycobacteria, Nocardia , and/or actinomycetes. 16S gene sequencing will be the primary identification method. In some situations, additional ancillary testing (ie, biochemicals, alternative sequencing) may also need to be performed. Susceptibility testing may be requested for an additional charge. The client submitting the isolate for…

Methodology

16S gene sequencing; ancillary sequencing and/or biochemical testing as required

Causes for rejection

Isolate nonviable; unlabeled specimen or name discrepancy between specimen and request label; broken tube or plate; mixed culture

Special instructions

This test first requires assessment of the kind of organism that will initiate a cascade reflex to the correct sequence primers. If reflex test is performed, additional charges/CPT code(s) may apply.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87153

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation