Quest Diagnostics test 16814, CPT 86038. Specimen: 1 mL serum.

ANA Cascade (ANA, IFA with Reflex to Titer and Pattern, and Reflex to 11 Ab Cascade) is Quest Diagnostics test code 16814, billed with CPT 86038. Specimen: 1 mL serum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code16814
CPT86038
LOINC—
Specimen1 mL serum Minimum volume
ContainerTransport tube
Storage / transportRoom temperature

Also known as: Calcinosis; Esophageal dysmotility; Systemic Lupus Erythematosus (SLE); Mixed Connective Tissue Disease; MCTD; FANA; Antinuclear Antibody Screen; Fluorescent ANA; Hep-2; Progressive ANA; Raynaud's phenomena; Sclerodactyly; Telangiectasia; Multiplex Cascade; Dermatomyositis; CREST

Methodology

Immunofluorescence Assay (IFA)

Stability

TemperaturePeriod
Room temperature4 days
Refrigerated7 days
Frozen30 days

Causes for rejection

Gross hemolysis • Grossly lipemic • Grossly icteric • Microbial contamination may interfere

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86038

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation