Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Antinuclear Antibodies (ANA), Qualitative, by Multiplex Immunoassay

Antinuclear Antibodies (ANA), Qualitative, by Multiplex Immunoassay: Labcorp test 164855

Labcorp test 164855, CPT 86038. Specimen: Serum. Turnaround: 1 - 3 days.

Antinuclear Antibodies (ANA), Qualitative, by Multiplex Immunoassay is Labcorp test code 164855, billed with CPT 86038. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code164855
CPT86038
LOINC8061-4
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 3 days
Storage / transportRoom temperature

Also known as: ANA Direct

Use

Detect antibodies to nuclear antigens

Methodology

Multiplex flow immunoassay

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Hemolysis; lipemia; gross bacterial contamination; icterus

Limitations

Males and females older than 80 years of age have a 50% incidence of low titer ANA. Various medications can induce a “lupoid” condition.

LOINC map

Result codeResult nameUnitsResult LOINC
164862ANA Direct8061-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86038

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation